High temporal resolution phase contrast MRI with multiecho acquisitions.
نویسندگان
چکیده
Velocity imaging with phase contrast (PC) MRI is a noninvasive tool for quantitative blood flow measurement in vivo. A shortcoming of conventional PC imaging is the reduction in temporal resolution as compared to the corresponding magnitude imaging. For the measurement of velocity in a single direction, the temporal resolution is halved because one must acquire two differentially flow-encoded images for every PC image frame to subtract out non-velocity-related image phase information. In this study, a high temporal resolution PC technique which retains both the spatial resolution and breath-hold length of conventional magnitude imaging is presented. Improvement by a factor of 2 in the temporal resolution was achieved by acquiring the differentially flow-encoded images in separate breath-holds rather than interleaved within a single breath-hold. Additionally, a multiecho readout was incorporated into the PC experiment to acquire more views per unit time than is possible with the single gradient-echo technique. A total improvement in temporal resolution by approximately 5 times over conventional PC imaging was achieved. A complete set of images containing velocity data in all three directions was acquired in four breath-holds, with a temporal resolution of 11.2 ms and an in-plane spatial resolution of 2 mm x 2 mm.
منابع مشابه
Is High Temporal Resolution Achievable for Paediatric Cardiac Acquisitions during Several Heart Beats? Illustration with Cardiac Phase Contrast Cine-MRI
BACKGROUND During paediatric cardiac Cine-MRI, data acquired during cycles of different lengths must be combined. Most of the time, Feinstein's model is used to project multiple cardiac cycles of variable lengths into a mean cycle. OBJECTIVE To assess the effect of Feinstein projection on temporal resolution of Cine-MRI. METHODS 1/The temporal errors during Feinstein's projection were compu...
متن کاملAccelerating time-resolved MRA with multiecho acquisition.
A new four-dimensional magnetic resonance angiography (MRA) technique called contrast-enhanced angiography with multiecho and radial k-space is introduced, which accelerates the acquisition using multiecho while maintaining a high spatial resolution and increasing the signal-to-noise ratio (SNR). An acceleration factor of approximately 2 is achieved without parallel imaging or undersampling by ...
متن کاملFMRI using high flip-angle alternating steady state balanced SSFP supported by Monte Carlo studies
Introduction The need exists for a functional MRI (fMRI) technique capable of artifact-free whole brain coverage, with good blood oxygenation level dependent (BOLD) contrast to noise ratio (CNR), and high temporal resolution. Conventional gradient echo (GRE) BOLD fMRI suffers from signal dropout in regions of magnetic field inhomogeneity, limiting coverage, while spin echo fMRI has reduced BOLD...
متن کاملUltrafast 3D spin-echo acquisition improves Gadolinium-enhanced MRI signal contrast enhancement
Long scan times of 3D volumetric MR acquisitions usually necessitate ultrafast in vivo gradient-echo acquisitions, which are intrinsically susceptible to magnetic field inhomogeneities. This is especially problematic for contrast-enhanced (CE)-MRI applications, where non-negligible T2* effect of contrast agent deteriorates the positive signal contrast and limits the available range of MR acquis...
متن کاملReal-time phase-contrast MRI of cardiovascular blood flow using undersampled radial fast low-angle shot and nonlinear inverse reconstruction.
Velocity-encoded phase-contrast MRI of cardiovascular blood flow commonly relies on electrocardiogram-synchronized cine acquisitions of multiple heartbeats to quantitatively determine the flow of an averaged cardiac cycle. Here, we present a new method for real-time phase-contrast MRI that combines flow-encoding gradients with highly undersampled radial fast low-angle shot acquisitions and phas...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Magnetic resonance in medicine
دوره 47 3 شماره
صفحات -
تاریخ انتشار 2002