A Double Transducer for High Precision Ultrasonic Time-Domain Reflectometry Measurements

نویسندگان

  • Sam Stade
  • Tuomas Hakkarainen
  • Mari Kallioinen
  • Mika Mänttäri
  • Tuure Tuuva
چکیده

Membrane fouling, where unwanted particles accumulate on the membrane surface and reduce its permeability, causes problems in membrane filtration processes. With ultrasonic time-domain reflectometry (UTDR) it is possible to measure the extent of membrane fouling and hence take actions to minimize it. However, the usability of UTDR is very limited to constant filtration conditions if the sonic velocity, which has a great impact on UTDR measurement accuracy, is unknown. With a reference transducer the actual sonic velocity can be measured. This requires another transducer to be installed in the module, where there may be only limited space or the module dimensions may not be suitable for the reference transducer. A double transducer described in this study eliminates the need for a separate reference transducer because in the double transducer the reference measurement is included in the design of the transducer holder. Two sensors in the same holder require less space. Other advantage is that the double transducer can be placed near the measurement target and hence the local sonic velocity can be determined.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Cable Length Measurement Systems Based on Time Domain Reflectometry

Based on the principle of time domain reflectometry(TDR) cable length measurement, the principle error of the TDR cable length measurement is analyzed. Methods for reducing cable length measurement error are analyzed. Two cable length measurement systems based on the TDR principle are designed. The high-precision time interval measurement module is the core of the first measurement system. The ...

متن کامل

The Development of CPLD-Based Ultrasonic Flowmeter

The measurement principle of the transit time difference method of the ultrasonic flowmeter is presented. The hardware structure and realization method are introduced. The software function and work mode are overviewed. In order to enhancing flowmeter's precision and stability a Xilinx CoolRunner CPLD and a Texas Instruments microcontroller from MSP430 family are applied in high precision timin...

متن کامل

Investigation of the Effect Soil particles size on the Currency Time Domain Reflectometry for water content measurement

This study carried out on the provided textures at laboratory. The provided textures were infusedinside the PVC cylinder with 30cm height and 25cm diameter. The studied textures were loamysand, sandy loam, sandy clay-loam, clay loam and clay. After 24 hours of saturation, the soil watercontent of the samples was measured by oven-dry gravimetric and TDR methods. For each texturesat any stage of ...

متن کامل

Measurements of the longitudinal wave speed in thin materials using a wideband PVDF transducer.

A flat transducer was constructed, using a 9-microm-thick PVDF (polyvinylidene fluoride) film for generation and detection of high-frequency ultrasonic waves, and used for measurements of the phase velocity of longitudinal waves traveling along the thickness direction in a very thin material. The transducer has a useful wideband frequency characteristic extending from 10 MHz to over 150 MHz. Me...

متن کامل

Moisture content measurements through TDR: a metrological assessment for industrial applications

In this paper a metrological assessment on the accuracy provided by a Time Domain Reflectometry (TDR)based method for the estimation of moisture content of granular materials is proposed. In particular, comparative moisture content measurements are carried out through two different TDR instruments: an inexpensive portable unit and a high-performance unit. The main goals are first to assess a ro...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره 15  شماره 

صفحات  -

تاریخ انتشار 2015