Absolute Measurement of Base Lines up to 400 M Using Temporal Coherence Heterodyne Interferometer of Optical Frequency Comb

نویسندگان

  • H. Matsumoto
  • X. Wang
  • K. Takamasu
چکیده

A heterodyne interference system is developed for base-lines measurement by using an acoustic optical modulator and a stabilized optical-frequency comb. The temporal coherence interference with the optical-frequency comb happen at discrete positions, where a pair of pulse trains overlaps with each other. An optical delay of the interferometer with a piezo-electric transducer is realized to find the peak position of interference fringe pattern and the absolute distance is obtained with a high accuracy. The interferometer is applied to a distance of base-lines up to 403 m and the experimental result shows of possibility of measuring within an accuracy of several micrometers.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Space position measurement using long-path heterodyne interferometer with optical frequency comb.

A heterodyne interference system was developed for position measurement. A stabilized optical-frequency comb is used as the laser source. The preliminary experiment to measure a distance of 22.478 m shows a drift of 1.6 μm in 20 minutes after the temperature compensation. Comparison and frequency shift experiments have been done for a distance of about 7.493 m. The experimental results show tha...

متن کامل

Error Analysis, Design and Modeling of an Improved Heterodyne Nano-Displacement Interferometer

A new heterodyne nano-displacement with error reduction is presented. The main errors affecting the displacement accuracy of the nano-displacement measurement system including intermodulation distortion error, cross-talk error, cross-polarization error and phase detection error are calculated. In the designed system, a He-Ne laser having three-longitudinal-mode is considered as the stabiliz...

متن کامل

Modeling of measurement error in refractive index determination of fuel cell using neural network and genetic algorithm

Abstract: In this paper, a method for determination of refractive index in membrane of fuel cell on basis of three-longitudinal-mode laser heterodyne interferometer is presented. The optical path difference between the target and reference paths is fixed and phase shift is then calculated in terms of refractive index shift. The measurement accuracy of this system is limited by nonlinearity erro...

متن کامل

Patel, Rikesh and Achamfuo-Yeboah, Samuel and Light, Roger and Clark, Matt (2012) Ultrastable heterodyne interferometer system using a CMOS modulated light

A novel ultrastable widefield interferometer is presented. This uses a modulated light camera (MLC) to capture and stabilise the interferogram in the widefield heterodyne interferometer. This system eliminates the contribution of piston phase to the interferogram without the need for common path optics and results in a highly stable widefield interferometer. The MLC uses quadrature demodulation...

متن کامل

Mode-resolved frequency comb interferometry for high-accuracy long distance measurement

Optical frequency combs have developed into powerful tools for distance metrology. In this paper we demonstrate absolute long distance measurement using a single femtosecond frequency comb laser as a multi-wavelength source. By applying a high-resolution spectrometer based on a virtually imaged phased array, the frequency comb modes are resolved spectrally to the level of an individual mode. Ha...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره   شماره 

صفحات  -

تاریخ انتشار 2012