Hydroxyapatite (HA) coating appears to be of benefit for implant durability of tibial components in primary total knee arthroplasty

نویسندگان

  • Jeffrey D Voigt
  • Michael Mosier
چکیده

BACKGROUND It is unclear whether there is a clinical benefit to adding hydroxyapatite (HA) coatings to total knee implants, especially with the tibial component, where failure of the implant more often occurs. A systematic review of the literature was undertaken to identify all prospective randomized trials for determining whether the overall clinical results (as a function of durability, function, and adverse events) favored HA-coated tibial components. METHODS A comprehensive literature search was performed for the years 1990 to September 16, 2010. We restricted our search to randomized controlled trials involving participants receiving either an HA-coated tibia or other forms of tibial fixation. The primary outcome measures evaluated were durability, function, and acute adverse events. RESULTS Data from 926 evaluable primary total knee implants in 14 studies were analyzed. Using an RSA definition for durability, HA-coated tibial components (porous or press-fit) without screw fixation were less likely to be unstable at 2 years than porous and cemented metal-backed tibial components (RR = 0.58, 95% CI: 0.34-0.98; p = 0.04, I(2) = 39%, M-H random effects model). There was no significant difference in durability, as measured from revision and evaluated at 2 and 8-10 years, between groups. Also, functional status using different validated measures showed no significant difference at 2 and 5 years, no matter what measure was used. Lastly, there was no significant difference in adverse events. Limitations included small numbers of evaluable patients (≤ 50) in 7 of the 14 trials identified, and a lack of "hard" evidence of durability with need for replacement (i.e. frank failure, pain, or loss of functionality). INTERPRETATION In patients > 65 years of age, an HA-coated tibial implant may provide better durability than other forms of tibial fixation. Larger trials should be undertaken comparing the long-term durability, function, and adverse events of HA-coated implants with those of other porous-coated tibial implants in younger, more active OA patients.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Acute Primary Total Knee Arthroplasty for Proximal Tibial Fractures in Elderly

Background: Proximal tibial fractures in elderly patients with osteoporosis or knee osteoarthritis (OA) are challengingcases. In the current study, we present our experience with uncommon acute primary total knee arthroplasty (PTKA)in this patient population.Methods: PTKAs were performed following proximal tibial fractures in 30 consecutive patients over 60 years of agewith osteoporosis or knee...

متن کامل

Hydroxyapatite augmentation of the porous coating improves fixation of tibial components. A randomised RSA study in 116 patients.

In a single-blind, randomised series of knee replacements in 116 patients, we used radiostereometric analysis (RSA) to measure micromotion in three types of tibial implant fixation for two years after knee replacement. We compared hydroxyapatite-augmented porous coating, porous coating, and cemented fixation of the same design of tibial component. At one to two years, porous-coated implants mig...

متن کامل

Long- Stem Total Knee Arthroplasty for Proximal Tibial Stress Fractures in the Elderly Patients

Background: Presentation of proximal tibia stress fracture is not infrequent among elderly patients due to their poorbone stock. Optimal management of patients with severe gonarthrosis of the knee and concurrent tibial stress fracture isnot known yet. In this study we report the outcome of primary total knee arthroplasty (TKA) using stemmed componentsin elderly patients.Methods: Between 2009 an...

متن کامل

How Much Bone Cement Is Utilized for Component Fixation in Primary Cemented Total Knee Arthroplasty?

Background: No scientific evidence exists regarding the amount of bone cement used and discarded in primarycemented Total knee arthroplasty (TKA). The aim of this study was to identify the exact amount of bone cement utilizedfor component fixation in primary TKA.Methods: In a prospective study carried out at five centers, 133 primary cemented TKAs were performed. One packof 40g Palacos bone cem...

متن کامل

Hydroxyapatite-coated femoral stems. Histology and histomorphometry around five components retrieved at post mortem.

We performed a histological and histomorphometric examination in five cadaver specimens of the femoral and acetabular components and the associated tissue which had been recovered between 3.3 and 6.2 years after primary total hip arthroplasty (THA) using a proximal hydroxyapatite (HA)-coated titanium alloy implant. All had functioned well during the patients' life. All the stems were fixed in t...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره 82  شماره 

صفحات  -

تاریخ انتشار 2011