On-line plasma lactate concentration monitoring in critically ill patients
نویسندگان
چکیده
Blood lactate concentration (BLC) is widely used to guide resuscitation in critically ill patients [1]. Muscular microdialysis has previously been used illustrate the importance of the Na/K pump in hyperlactatemia in septic shock patients [2], with BLC reflecting metabolic changes rather than oxygen debt [3]. Microdialysis has now also been applied to intravascular continuous monitoring [4] (Eirus TLC®, Maquet Critical Care, Solna, Sweden). Nevertheless, the potential clinical implications of on-line lactate monitoring are unclear. In this regard, we illustrate the high sensitivity of the device to detect BLC variations and the potential clinical implications of this. An adult patient presented with a total body surface area burn of 70% after a suicide attempt by selfimmolation. A triple-lumen central venous catheter (CVC) with an integrated microdialysis function was placed in the left internal jugular vein. A second CVC was placed in the right femoral vein. Figure 1 shows BLC variation during the first hours after resuscitation. On top of the general trend of BLC assessment, we propose an alternative additional use of continuous BLC monitoring, namely assessment of blood lactate clearance [5]. A short-lasting rise in BLC can be identified in the global trends (circles in Fig. 1a) corresponding to fluid challenges using Ringer lactate (RL; 500 ml, lactate 29 mmol/L, amount of lactate 14.5 mmol). Lactate clearance can be assessed using the flowing formula: Lc (L/kg/h) = D (mmol/kg)⁄AUC (mmol/L/h), where Lc is lactate clearance, D is the amount of L-lactate infused, and AUC is the area under the curve from RL infusion until BLC reaches its initial level. Two RL bolus infusions via the femoral CVC performed with a 2-h interval (Fig. 1b) allowed us to evaluate lactate clearance at 934 and 1172 ml/min, respectively [5]). The AUC was calculated by the trapezoid method, i.e., the sum of BLC means every minute, with the BLC at initiation of the RL infusion used as the reference (Fig. 1c). Lactate production was calculated to be 3518 and 3176 μmol/kg/ h, respectively, as lactate production (μmol/kg/h) = blood lactate (mmol/L) × lactate clearance (mL/kg/h) [5]. Intermeasurement variability was 16 and 7%, respectively, for lactate production and clearance. To summarize, this case illustrates that continuous monitoring could allow sensitive detection of rapid and short-lasting changes in BLC after a 500-ml RL infusion. This could be used to assess lactate clearance. Further studies are needed to validate this concept.
منابع مشابه
How rational Aminoglycosides are being used in critically ill patients? Results from a teaching hospital in north of Iran
Background: Resistance to antimicrobial agents including aminoglycosides (AGs) is a great concern that is mainly related to inappropriate use. Since there were not adequate data regarding how rationally AGs are being prescribed in our critically ill patients, this study was conducted to determine the main issues in the area of appropriate use of this antibiotic class. Methods: One hundred...
متن کاملMetformin Treatment in Hyperglycemic Critically Ill Patients: Another Challenge on the Control of Adverse Outcomes
New-onset hyperglycemia in patients admitted to intensive care units increases the risk of morbidity and mortality. Insulin resistance is frequently seen in the treatment of stress-induced hyperglycemia. Metformin, an oral anti-hyperglycemic agent, may introduce a new treatment protocol in critically ill patients with insulin-resistance hyperglycemia. Fifty-one non-diabetic traumatized patients...
متن کاملMetformin Treatment in Hyperglycemic Critically Ill Patients: Another Challenge on the Control of Adverse Outcomes
New-onset hyperglycemia in patients admitted to intensive care units increases the risk of morbidity and mortality. Insulin resistance is frequently seen in the treatment of stress-induced hyperglycemia. Metformin, an oral anti-hyperglycemic agent, may introduce a new treatment protocol in critically ill patients with insulin-resistance hyperglycemia. Fifty-one non-diabetic traumatized patients...
متن کاملLactate revisited : is lactate monitoring beneficial for ICU patients ? REVIEw
Blood lactate levels are frequently measured in critically ill patients. Whilst these measurements are known to be accurate, for the correct interpretation of hyperlactataemia, it is essential to have sufficient understanding of anaerobic and aerobic mechanisms of production and clearance. The consistency of the prognostic value emphasizes the place of lactate measurement in the risk-stratifica...
متن کاملDysoxia and lactate.
Disturbances of oxygen supply or cellular oxygen metabolism are common in critically ill patients. An understanding of dysoxia, or oxygen limited energy depletion, requires an understanding of the normal physiology of cell oxygen metabolism, and the compensatory mechanisms that supply high energy molecules under conditions of hypoxia. Understanding disorders associated with hyperlactataemia req...
متن کامل