How to Appropriately Calculate Effective Dose for CT Using Either Size-Specific Dose Estimates or Dose-Length Product.

نویسندگان

  • Samuel L Brady
  • Amy E Mirro
  • Bria M Moore
  • Robert A Kaufman
چکیده

OBJECTIVE The purpose of this study is to show how to calculate effective dose in CT using size-specific dose estimates and to correct the current method using dose-length product (DLP). MATERIALS AND METHODS Data were analyzed from 352 chest and 241 abdominopelvic CT images. Size-specific dose estimate was used as a surrogate for organ dose in the chest and abdominopelvic regions. Organ doses were averaged by patient weight-based populations and were used to calculate effective dose by the International Commission on Radiological Protection (ICRP) report 103 method using tissue-weighting factors (EICRP). In addition, effective dose was calculated using population-averaged CT examination DLP for the chest and abdominopelvic region using published k-coefficients (EDLP = k × DLP). RESULTS EDLP differed from EICRP by an average of 21% (1.4 vs 1.1) in the chest and 42% (2.4 vs 3.4) in the abdominopelvic region. The differences occurred because the published kcoefficients did not account for pitch factor other than unity, were derived using a 32-cm diameter CT dose index (CTDI) phantom for CT examinations of the pediatric body, and used ICRP 60 tissue-weighting factors. Once it was corrected for pitch factor, the appropriate size of CTDI phantom, and ICRP 103 tissue-weighting factors, EDLP improved in agreement with EICRP to better than 7% (1.4 vs 1.3) and 4% (2.4 vs 2.5) for chest and abdominopelvic regions, respectively. CONCLUSION Current use of DLP to calculate effective dose was shown to be deficient because of the outdated means by which the k-coefficients were derived. This study shows a means to calculate EICRP using patient size-specific dose estimate and how to appropriately correct EDLP.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Radiation dose of Pediatrics in a general hospital in comparison to a pediatrics hospital

Introduction: Increasing CT scan application increased the cancer risk in pediatrics in recent decays. Imaging centers approach for diagnosis of disease cause to different radiation dose to patients.  Because  of  rapid  pediatrics  body  growth,  the  most  important  challenge to determining the radiation dose is wide variations of size in different ages. Thus, we used Size...

متن کامل

Thorax organ dose estimation in computed tomography based on patient CT data using Monte Carlo simulation

Background:  This study presents patient specific and organ dose estimation in computed tomography (CT) imaging of thorax directly from patient CT image using Monte Carlo simulation.  Patient's CT image is considered as the patient specific phantom and the best representative of patient physical index in order to calculate specific organ dose. Materials and Methods: EGSnrc /BEAMnr...

متن کامل

Diagnostic Reference Levels for Computed Tomography Examinations in Iran: A Nationwide Radiation Dose Survey

Introduction: International Commission on Radiological Protection introduced three basic principles of radiation protection, namely justification, optimization, and dose limit. Medical exposure has no dose limits, and generally, diagnostic reference levels are used as a tool for optimization of patient protection. Material and Methods: Dosimetry was performed on 20 CT scanners located in 14 cit...

متن کامل

Establishment of Diagnostic Reference Levels and Estimation of Effective Dose from Computed Tomography Head Scans at a Tertiary Hospital in South Africa

Introduction: Head scans are the most frequently performed computed tomography (CT) examinations worldwide. However, there is growing concern over the probability of increased cancer risks among the exposed populations. Diagnostic reference levels (DRLs) identify radiation dose that is not commensurate with clinical objectives. The aim of this study was to establish DR...

متن کامل

بررسی دز مؤثر دریافتی بیماران در تصویربرداری استخوان تمام بدن به روش اسپکت-سی تی ناشی از تصویربرداری عبوری، در بخش پزشکی هسته‌ای بیمارستان دکتر شریعتی

Introduction: whole body bone scan is one of the most useful procedures of nuclear medicine. Accurate distribution of radiopharmaceutical is yielded by using SPECT-CT. There are concerns about the radiation dose of CT part. The present study aimed to evaluate the patients’ dose in bone nuclear medicine imaging. Methods and Materials: First of all, the dose report of CT console was calibrated u...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • AJR. American journal of roentgenology

دوره 204 5  شماره 

صفحات  -

تاریخ انتشار 2015