Comparison of different methods of incorporating respiratory motion for lung cancer tumor volume delineation on PET images: a simulation study.
نویسندگان
چکیده
The interest of PET complementary information for the delineation of the target volume in radiotherapy of lung cancer is increasing. However, respiratory motion requires the determination of a functional internal target volume (ITV) on PET images for which several strategies have been proposed. The purpose of this study was the comparison of these strategies for taking into account respiratory motion and deriving the ITV: (1) adding fixed margins to the volume defined on a single binned image, (2) segmenting a motion averaged image and (3) considering the union of volumes delineated on binned frames. For this third strategy, binned frames were either non-corrected for motion, or corrected using two different methods: elastic registration or super resolution. The strategies' performances were assessed on realistic simulated datasets combining the NCAT phantom with a PET Philips GEMINI scanner model in GATE, and containing various configurations of tumor to background contrast, with both regular and irregular respiratory motion (with a range of motion amplitudes). The obtained ITVs' sensitivity (SE) and positive predictive value (PVE) with respect to the known true ITV were significantly higher (from 0.8 to 0.95) than all other techniques when using binned frames corrected for motion, independently of motion regularity, amplitude, or tumor to background contrast. Although the absolute difference was small and not always significant, images corrected using super resolution led to systematically better results than using elastic registration. The worst results were obtained when using the motion averaged image for SE (around 0.5-0.6) and using the margins added to a single frame for PPV (0.6-0.7), respectively. The best strategy to account for breathing motion for tumor ITV delineation in radiotherapy planning is to rely on the use of the union of volumes delineated on super resolution-corrected binned images.
منابع مشابه
Comparison of PET/CT and CT-based tumor delineation and its effects on the radiation treatment planning for non-small cell lung cancer
Introduction: Tumor volume delineation is the most important step in the radiation treatment planning. In this study the impact of PET/CT data on the tumor delineation precision of non-small cell lung cancer (NSCLC) was investigated. Methods: PET/CT images of 20 patients with primary NSCLC were obtained and imported to the treatment planning system for im...
متن کاملEvaluation of methods of co-segmentation on PET/CT images of lung tumor: simulation study
Introduction: Lung cancer is one of the most common causes of cancer-related deaths worldwide. Nowadays PET/CT plays an essential role in radiotherapy planning specially for lung tumors as it provides anatomical and functional information simultaneously that is effective in accurate tumor delineation. The optimal segmentation method has not been introduced yet, however several ...
متن کاملRespiratory motion correction in prostate cancer positron emission tomography: A study on patients and phantom simulation
Introduction: To investigate the effects of breathing cycle and tree diaphragm motions on prostate cancer tumors standard uptake value (SUV) during positron emission tomography (PET) and to correct it. Materials and methods: Respiratory motion traces were simulated on the common patient breathing cycle and tree diaphragm motio...
متن کاملImpact of Various Image Reconstruction Methods on Joint Compensation of Respiratory Motion and Partial Volume Effects in Whole-Body 18F-FDG PET/CT Imaging: Patients with Non-Small Cell Lung Cancer
Background: The present study aims to assess the impact of various image reconstruction methods in 18F-FDG PET/CT imaging on the quantification performance of the proposed technique for joint compensation of respiratory motion and partial volume effects (PVEs) in patients with non-small cell lung cancer. Materials and Methods: An image-based deconvolution technique was proposed, incorporating w...
متن کاملBackground-Based Delineation of Internal Tumor Volumes on Static Positron Emission Tomography in a Phantom Study
Objective(s): Considering the fact that the standardized uptake value (SUV) of a normal lung tissue is expressed as x±SD, x+3×SD could be considered as the threshold value to outline the internal tumor volume (ITV) of a lung neoplasm. Methods: Three hollow models were filled with 55.0 kBq/mL fluorine18- fluorodeoxyglucose (18F-FDG) to represent tumors. The models were fixed to a barrel filled w...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Physics in medicine and biology
دوره 57 22 شماره
صفحات -
تاریخ انتشار 2012