Fatigue cyclic loading test of an auro-galvanoforming ceramic bridge.

نویسندگان

  • Xiang-hao Zhang
  • Feng Sun
  • Huan Wang
  • Man-qiong Xu
چکیده

BACKGROUND In dental clinics, dentition defects are commonly restored with conventional porcelain-fused-to-metal fixed bridges. However, Ni-Cr alloy ceramic fixed bridges are known to have several drawbacks such as marginal coloration of the neck, low casting precision and, most seriously, poor biocompatibility. These problems could be circumvented by using noble metal ceramic bridges; however, one negative issue related to the conventional noble metal ceramic bridges is its high price due to the use of a large amount of gold for pontic. Therefore, an auro-galvanoforming ceramic bridge would be ideal to retain the advantages of a conventional material, yet reduce the amount of noble metal used. This study aimed to investigate whether any destructive changes occur to the auro-galvanoforming ceramic bridge under a fatigue cyclic loading test. METHODS On standard models which the left maxillary first premolar is lost and with the cuspid teeth and the second premolar as the fixed bridge abutment teeth, six maxillary auro-galvanoforming ceramic bridges and six corresponding nichrome ceramic jointed crowns were made as group A, six nichrome ceramic bridges and six corresponding nichrome ceramic jointed crowns were made as group B (control group). And then all specimens were fixed and tested on a fatigue cyclic loading machine; the changes occurring to the surfaces of occlusal contact with large functional area and to the porcelain-metal interfaces of the nichrome primary copings margins were observed through a scanning electron microscope (SEM). RESULTS In 120 hours' continual observation, none of the specimens had porcelain coating fractures or scraping occurrence and all of the porcelain coatings had been kept intact under sinusoidal cyclic loading with the load range of 120 - 200 N and frequency of 5 Hz. CONCLUSIONS Auro-galvanoforming ceramic bridges exhibited excellent fatigue strength in the fatigue cyclic loading test and may satisfy the clinical demand in theory, while the practical application shall be evaluated by observations in long-term clinical usage.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Fatigue Lifetime of Ceramic Matrix Composites at Intermediate Temperature by Acoustic Emission

The fatigue behavior of a Ceramic Matrix Composite (CMC) at intermediate temperature under air is investigated. Because of the low density and the high tensile strength of CMC, they offer a good technical solution to design aeronautical structural components. The aim of the present study is to compare the behavior of this composite under static and cyclic loading. Comparison between incremental...

متن کامل

Sintered feldspathic and leucite reinforced ceramic are used for the fabrication of metal-free restorations

New ceramic materials, like hot-pressed glass ceramics can be used to achieve monolithic full anatomic all-ceramic dental restorations even in the molar areas. Due to the fact that these materials are brittle and susceptible to fracture, the aim of the study was to reveal the fracture behaviour of hot-pressed glass ceramic molar crowns under different loading methods. For the experimental analy...

متن کامل

Load Controlled Fatigue of AZ31B

With the expanding demand on application of magnesium alloys in automotive and aerospace industries, robust methods in fatigue characterization of commercially available magnesium alloys with high specific strength is anticipated. In this paper, rotating bending load controlled tests has been studied on specimens machined from an extrusion piece of AZ31B. Due to asymmetric and anisotropic behav...

متن کامل

Low Cycle Fatigue Simulation of Valve Bridge Region in Cylinder Head Based on Critical Plane Model

The reason of this study is low cycle failure of cast iron cylinder head during the E5 standard durability test. The goal of the present investigation is durability test simulation and low cycle fatigue life evaluation of cast iron cylinder head. With uncouple structural analysis, preloads, thermal and mechanical load and boundary conditions are prescribed to finite element model of the cylinde...

متن کامل

Fatigue Damage and Lifetime of SiC/SiC Ceramic-Matrix Composite under Cyclic Loading at Elevated Temperatures

In this paper, the fatigue damage and lifetime of 2D SiC/SiC ceramic-matrix composites (CMCs) under cyclic fatigue loading at 750, 1000, 1100, 1200 and 1300 °C in air and in steam atmosphere have been investigated. The damage evolution versus applied cycles of 2D SiC/SiC composites were analyzed using fatigue hysteresis dissipated energy, fatigue hysteresis modulus, fatigue peak strain and inte...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Chinese medical journal

دوره 121 19  شماره 

صفحات  -

تاریخ انتشار 2008