Thermoelectrically cooled temperature-gradient apparatus for comparative cell and virus temperature studies.
نویسندگان
چکیده
Establishment of a near-linear temperature gradient in an incubator has been accomplished by the application of heat to one terminus of a conducting body, normally a metal bar, and the removal of heat from the other terminus of the conducting body. Such incubators have been complex and unwieldy because of the need for mechanical refrigeration. We have described a simplified temperature gradient incubator which uses thermoelectric module cooling coupled with electric heating. Along the gradient, 20 stations in two parallel rows of 10, each accommodating a 30-ml plastic cell culture flask, were continually monitored by an electronic thermometer, and the temperatures were recorded. By manipulation of two simple potentiometer controls, any temperature gradient between 0 and 50 C could be obtained. Minor deviations which occurred between theoretically perfect and obtained temperature gradients were reproducible and readily measured. The gradient incubator was particularly applicable to (i) simultaneously studying a given biological activity over the entire temperature range supporting the growth of a given cell, virus, or microorganism, or (ii) precisely defining the upper or lower temperature limits of a biological system by 10-point determinations. Preliminary experiments have demonstrated the usefulness of the apparatus in characterizing the temperature limits for growth in vitro of cells of reptilian cell lines. The gradient incubator was also successfully utilized for the characterization of the effect of temperature on the efficiency of plating of amphibian viruses and possible temperature variants of those viruses.
منابع مشابه
An experimental technique for measuring the temperature rise during impact testing
A fast response radiometer and its associated instrumentation for the measurement of the temperature reached during impact is described in this paper. It is based on a thermoelectrically cooled HgCdTe detector. The sensitivity and time response have been determined by means of static calibration tests, within the range +25 to 500 "C, and a dynamic calibration using an optical chopper at 1.35 kH...
متن کاملInfrared pyrometer for temperature measurement of objects , emissivity of which depends on wavelength and time
The multiband MBP 98A pyrometer developed for non-contact temperature measurement of objects with unknown and wavelength-dependent emissivity has been presented in this paper. The pyrometer was designed using single thermoelectrically cooled PbS detector of spectral band of 1-2.5 Ilm and 8 narrow-band optical filters. It enables temperature measurement of objects at temperature within a range o...
متن کاملProtocols for the high temperature measurement of the Seebeck coefficient in thermoelectric materials
In Seebeck coefficient metrology, the present diversity in apparatus design, acquisition methodology and contact geometry has resulted in conflicting materials data that complicate the interlaboratory confirmation of reported high efficiency thermoelectric materials. To elucidate the influence of these factors in the measurement of the Seebeck coefficient at high temperature and to identify opt...
متن کاملEvaluating the Effects of Ceramic Layer and Thermal Dam on Optimizing the Temperature Gradient of a Gasoline Engine Piston (TECHNICAL NOTE)
The purpose of this paper is to evaluate the effect of different methods for improving the temperature gradient of a specified gasoline engine piston. With a robust FE based software, 3D thermal analyses have been carried out for the piston model. Unlike previous studies, the effects of both fully and locally ceramic layers on the crown top surface were considered. It was found that a fully cer...
متن کاملRoom-temperature mid-infrared laser sensor for trace gas detection.
Design and operation of a compact, portable, room-temperature mid-infrared gas sensor is reported. The sensor is based on continuous-wave difference-frequency generation (DFG) in bulk periodically poled lithium niobate at 4.6 mum, pumped by a solitary GaAlAs diode laser at 865 nm and a diode-pumped monolithic ring Nd:YAG laser at 1064.5 nm. The instrument was used for detection of CO in air at ...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Applied microbiology
دوره 19 5 شماره
صفحات -
تاریخ انتشار 1970