Liquid Heparin Anticoagulant Produces More Negative Bias in the Determination of Ionized Magnesium than Ionized Calcium

نویسندگان

  • Cheung Soo Shin
  • Chul Ho Chang
  • Jeong-Ho Kim
چکیده

The ionized calcium level in blood is known to be falsely decreased when self-prepared liquid heparin anticoagulant is used, due to dilution and binding effects. The effect of liquid heparin on the determination of ionized magnesium is not as well understood. We compared the effect of liquid sodium heparin on the determination of ionized calcium and magnesium in 44 clinical samples using two types of user-prepared heparin syringes which differed in the amount of residual heparin from the BD Preset reference syringe. With the type 1 syringe, the liquid heparin was expelled once or twice such that some heparin could be left in the dead space at the syringe hub, while the liquid sodium heparin was thoroughly expelled from the type 2 syringe. The ionized magnesium levels obtained with the type 1 syringe were significantly lower than the reference value (by 0.068 mmol/L) (p < 0.0001), while the value obtained with the type 2 syringe differed less from the reference, by only 0.014 mmol/L (p < 0.0001). The heparin binding effect resulted in more negative bias in ionized magnesium (- 0.026 +/- 0.032 mmol/L) than in ionized calcium (- 0.009 +/- 0.042 mmol/L, p < 0.0001). In conclusion, we recommend using lyophilized, calcium-balanced, heparinized syringes for the determination of ionized magnesium and ionized calcium due to the increased negative bias in ionized magnesium determinations. When user-prepared syringes are used, the thorough evacuation of heparin solution should be strictly prescribed.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

D-phenylalanyl-L-prolyl-L-arginine chloromethyl ketone (PPACK): alternative anticoagulant to heparin salts for blood gas and electrolyte specimens.

D-Phenylalanyl-L-prolyl-L-arginine chloromethyl ketone (PPACK), a selective thrombin inhibitor, was evaluated as an alternative anticoagulant to lithium heparin (LiHep) for blood gas and whole-blood electrolyte analyses. Initial studies in serum revealed a negative proportional bias for ionized calcium (iCa) concentration measured in the range of increasing concentrations of LiHep (-0.02 mmol/L...

متن کامل

Analytical evaluation of Kone Microlyte determination of ionized magnesium.

We performed an analytical evaluation of a commercially available instrument for determining ionized magnesium through use of a neutral carrier, liquid-membrane-based ion-selective electrode. Reproducibility (CV 2-4%), linearity (0.30-2.50 mmol/L), lower limit of detection (0.30 mmol/L), and absence of interference from Ca2+ indicate adequate performance for measuring ionized magnesium in plasm...

متن کامل

Self-prepared heparinized syringes for measuring ionized magnesium in critical care patients.

We have compared ionized magnesium assays in the Nova 8 electrolyte analyser using dry balanced heparinized syringes and self-prepared heparinized syringes. Thirty blood specimens were obtained into syringes either operator-prepared with liquid sodium heparin or commercially manufactured dry balanced heparinized syringes. There was a good correlation between results from the two syringes. The m...

متن کامل

Effect of hematocrit and added heparin on ionized calcium in capillary blood samples from neonates.

Sampling of capillary blood for determination of ionized calcium (Ca2+) in neonates requires that extra heparin be added to prevent clotting in the sampling tube and (or) in the Ca2+ analyzer. Because the additive dissolves in the plasma compartment, different hematocrit (erythrocyte volume fraction, EVF) values may cause different results for Ca2+. To study the effect of EVF and heparin additi...

متن کامل

Ionized calcium: its significance and clinical usefulness.

Maintenance of normal blood levels of ionized calcium (Ca2+) plays an important role in the management of the critically ill patient. Therefore, Ca2+ should be collected properly and measured reliably. The sound analytical performance of today's Ca2+ analyzers using ion-selective electrode technology have made measurements accurate and precise. The introduction of this technology allows rapid a...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره 47  شماره 

صفحات  -

تاریخ انتشار 2006