Optimising Quantisation Noise in Energy Measurement
نویسندگان
چکیده
We give a model of parallel distributed genetic improvement. With modern low cost power monitors; high speed Ethernet LAN latency and network jitter have little effect. The model calculates a minimum usable mutation effect based on the analogue to digital converter (ADC)’s resolution and shows the optimal test duration is inversely proportional to smallest impact we wish to detect. Using the example of a 1 kHz 12 bit 0.4095 Amp ADC optimising software energy consumption we find: it will be difficult to detect mutations which an average effect less than 58μA, and typically experiments should last well under a second.
منابع مشابه
An Improved Clock-skew Measurement Technique for Revealing Hidden Services
The Tor anonymisation network allows services, such as web servers, to be operated under a pseudonym. In previous work Murdoch described a novel attack to reveal such hidden services by correlating clock skew changes with times of increased load, and hence temperature. Clock skew measurement suffers from two main sources of noise: network jitter and timestamp quantisation error. Depending on th...
متن کاملOptimisation of JPEG XR Quantisation Settings in Iris Recognition Systems
JPEG XR is considered as a lossy sample data compression scheme in the context of iris recognition techniques. It is shown that by optimising the JPEG XR quantisation strategy, JPEG XR default quantisation as well as JPEG2000 based iris recognition can be improved in terms of EER. The optimised JPEG XR quantisation strategy shows good performance across a wide range of iris feature extraction t...
متن کاملRoundoff Noise Analysis in Digital Systems for Arbitrary Sampling Rate Conversion
In this contribution the impact of finite signal wordlengths on the performance of digital systems for arbitrary sampling rate conversion (ASRC), where input and output sampling rates are derived from independent clock generators, is investigated. For two different approaches to ASRC the noise power due to both, input/output quantisation and multiplication roundoff errors, is determined as a fu...
متن کاملObjective Measurement of Image Quality in Fluoroscopic X-ray Equipment: Fluoroquality
The report describes FluoroQuality, a computer program that is developed in STUK and used for measuring the image quality in medical fluoroscopic equipment. The method is based on the statistical decision theory (SDT) and the main measurement result is given in terms of the accumulation rate of the signal-to-noise ratio squared (SNRrate). In addition to this quantity several other quantities ar...
متن کاملEfficient Linearisation of Sigma-Delta Modulators using Single-Bit Dither
Sigma-delta modulation, where a single-bit quantiser is embedded within a negative feedback loop (Fig. 1), is now a commonly-used technique for implementing high-resolution analogue-to-digital and digital-toanalogue converters (DACs), principally because of a favourable insensitivity to component tolerancing [1]. Single-bit quantisation generates relatively high levels of quantisation noise, he...
متن کامل