Influence of expanded balloon diameter on Palmaz-Schatz stent recoil.

نویسندگان

  • E Rechavia
  • F Litvack
  • G Macko
  • N L Eigler
چکیده

After successful stent implantation, the residual luminal diameter of the stented vessel is usually smaller than the maximal stent-expanded balloon diameter. The goal of this study was to determine whether immediate vessel diameter recoil after Palmaz-Schatz stenting is affected by the final expanding balloon diameter used during stent deployment. Single Palmaz-Schatz balloon expandable stents were successfully placed in 108 stenotic lesions. There were 68 patients with 75 saphenous vein graft (SVG) and 30 patients with 33 native coronary artery lesions, including 26 restenotic and 82 de novo occlusive (> 50% diameter stenosis) lesions. Quantitative coronary angiography was used for the assessment of stent recoil, defined as the difference between the minimal diameter of the fully expanded balloon and the postprocedure minimal lumen diameter divided by minimal diameter of the fully expanded balloon. A strong correlation (r = 0.94) was found between the minimal diameter of the fully expanded balloon and poststenting minimal lumen diameter. Immediate recoil was 11.3 +/- 7.5%, responsible on an average for 0.4 +/- 0.2-mm acute lumen loss. Recoil was less in SVG than in coronary arteries (9.7 +/- 6.6% vs. 14.0 +/- 7.8%; P = 0.004, and 0.3 +/- 0.2 vs. 0.4 +/- 0.2 mm; p = 0.01). Lesions were divided into four subgroups, based on the final stent expanding balloon diameter: (1) < or = 3.0 mm (n = 33); (2) > 3 < or = 3.5 mm (n = 43); (3) > 3.5 < or = 4 mm (n = 23); and (4) > 4 mm (n = 9).(ABSTRACT TRUNCATED AT 250 WORDS)

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Superimposed stents in the management of acute recoil after Palmaz-Schatz stenting.

We report a patient in whom aorto-ostial stenting with a Palmaz-Schatz coronary stent was complicated by significant acute elastic recoil, despite appropriate positioning of the stent and full expansion of a high-pressure, postdilatation balloon. Superimposing a Palmaz biliary stent overcame the inward radial force of this lesion and achieved an adequate lumen.

متن کامل

In vivo assessment of stent expansion and recoil in normal porcine coronary arteries: differential outcome by stent design.

BACKGROUND Despite the routine use of high pressure, coronary stents generally fail to achieve a cross-sectional area (CSA) >60% to 80% of the nominal CSA of their dilating balloon. The extent to which incomplete balloon expansion and postdeflation stent recoil contribute to this failure has not been fully evaluated. METHODS AND RESULTS Thirty-two stents (8 Gianturco-Roubin II, 8 Palmaz-Schat...

متن کامل

Mechanisms of residual lumen stenosis after high-pressure stent implantation: a quantitative coronary angiography and intravascular ultrasound study.

BACKGROUND Intravascular ultrasound (IVUS) studies have demonstrated that stents are frequently suboptimally expanded despite the use of high pressures for deployment. The purpose of this study was to identify the mechanisms responsible for such residual lumen stenosis. METHODS AND RESULTS Fifty-seven lesions from 50 patients treated with high-pressure (median+/-interquartile range, 14+/-2 at...

متن کامل

Increasing arterial wall injury after long-term implantation of two types of stent in a porcine coronary model.

AIMS There is increased late loss in luminal diameter following long-term coronary stenting, compared with balloon angioplasty. We evaluated short- and long-term vessel wall injury after experimental implantation of two stent designs as well as balloon angioplasty and their relationship to neointimal hyperplasia. METHODS AND RESULTS Wiktor stents and Palmaz-Schatz stents were implanted in nor...

متن کامل

Benefit of intracoronary ultrasound in the deployment of Palmaz-Schatz stents.

OBJECTIVES This study was designed to evaluate the changes in intrastent and angiographic dimensions when intravascular ultrasound imaging is used to direct the deployment of balloon-expandable Palmaz-Schatz stents in coronary arteries and saphenous vein grafts. BACKGROUND Intravascular ultrasound provides more information than angiography in the imaging of intravascular structures. Previous ...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:
  • Catheterization and cardiovascular diagnosis

دوره 36 1  شماره 

صفحات  -