Commissioning and periodic tests of the Esteya® electronic brachytherapy system
نویسندگان
چکیده
A new electronic brachytherapy unit from Elekta, called Esteya(®), has recently been introduced to the market. As a part of the standards in radiation oncology, an acceptance testing and commissioning must be performed prior to treatment of the first patient. In addition, a quality assurance program should be implemented. A complete commissioning and periodic testing of the Esteya(®) device using the American Association of Physicists in Medicine (AAPM), Groupe Européen de Curiethérapie and the European Society for Radiotherapy & Oncology (GEC-ESTRO) guidelines for linacs and brachytherapy units as well as our personal experience is described in this paper. In addition to the methodology, recommendations on equipment required for each test are provided, taking into consideration their availability and traceability of the detectors. Finally, tolerance levels for all the tests are provided, and a specific frequency for each test is suggested.
منابع مشابه
Dosimetric characteristics of a new unit for electronic skin brachytherapy
PURPOSE Brachytherapy with radioactive high dose rate (HDR) (192)Ir source is applied to small skin cancer lesions, using surface applicators, i.e. Leipzig or Valencia type. New developments in the field of radiotherapy for skin cancer include electronic brachytherapy. This technique involves the placement of an HDR X-ray source close to the skin, therefore combining the benefits of brachythera...
متن کاملClinical implementation of a new electronic brachytherapy system for skin brachytherapy
Although surgery is usually the first-line treatment for nonmelanoma skin cancers, radiotherapy (RT) may be indicated in selected cases. Radiation therapy as primary therapy can result in excellent control rates, cosmetics, and quality of life. Brachytherapy is a radiation treatment modality that offers the most conformal option to patients. A new modality for skin brachytherapy is electronic b...
متن کاملEfficacy and safety of electronic brachytherapy for superficial and nodular basal cell carcinoma
PURPOSE Surface electronic brachytherapy (EBT) is an alternative radiotherapy solution to external beam electron radiotherapy and high-dose-rate radionuclide-based brachytherapy. In fact, it is also an alternative solution to surgery for a subgroup of patients. The objective of this work is to confirm the clinical efficacy, toxicity and cosmesis of a new EBT system, namely Esteya(®) in the trea...
متن کاملIndependent assessment of source transit time for the BEBIG SagiNova® high dose rate brachytherapy afterloader
Introduction: The dwell time and transit time components contribute to the overall delivered dose to patients in high dose rate (HDR) brachytherapy treatments. The transit time results from source entry and exit as well as source movements between dwell positions. It depends on various parameters such as the source speed profile, source indexer distance to dwell position, and ...
متن کاملA commissioning procedure for breast intracavitary electronic brachytherapy systems
In this work, we report a comprehensive quality assurance (QA) process for the commissioning of an Electronic Brachytherapy (EB) system at one of the first U.S. sites to apply the device clinically. Thus far, EB systems have been released only for intracavitary breast treatments. As such, EB as an Accelerated Partial Breast Irradiation (APBI) treatment modality is relatively unstudied and is un...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
عنوان ژورنال:
دوره 7 شماره
صفحات -
تاریخ انتشار 2015