Validation of haemodialysis recirculation and access blood flow measured by thermodilution.
نویسندگان
چکیده
BACKGROUND Recirculation (R) and access blood flow (Qac) measurements are considered useful indicators of adequate delivery of haemodialysis. It was the purpose of this study to compare measurements of R and Qac obtained by two different techniques which are based on the same principle of indicator dilution, but which differ because of the characteristics of the injection and detection of the different indicators used. METHODS Recirculation measured by a thermal dilution technique using temperature sensors (BTM, Fresenius Medical Care) was compared with recirculation measured by a validated saline dilution technique using ultrasonic transducers placed on arterial and venous segments of the extracorporeal circulation (HDM, Transonic Systems, Inc.). Calculated access flows were compared by Bland Altman analysis. Data are given as mean +/- SD. RESULTS A total of 104 measurements obtained in 52 treatments (17 patients, 18 accesses) were compared. Recirculation measured with correct placement of blood lines and corrected for the effect of cardiopulmonary recirculation using the 'double recirculation technique' was -0.02 +/- 0.14% by the BTM technique and not different from the 0% measured by the HDM technique. Recirculation measured with reversed placement of blood lines and corrected for the effect of cardiopulmonary recirculation was 19.66 +/- 10.77% measured by the BTM technique compared with 20.87 +/- 11.64% measured by the HDM technique. The difference between techniques was small (-1.21 +/- 2.44%) albeit significant. Access flow calculated from BTM recirculation was 1328 +/- 627 ml/min compared with 1390 +/- 657 ml/min calculated by the HDM technique. There was no bias between techniques. CONCLUSION BTM thermodilution yields results which are consistent with the HDM ultrasound dilution technique with regard to both recirculation and access flow measurement.
منابع مشابه
Stability of access resistance during haemodialysis.
BACKGROUND Access blood flow (Qac) is considered a useful indicator in the surveillance of haemodialysis access function. However, changes in Qac may be due to changes in blood pressure and/or to changes in access resistance (AR). METHODS Weekly readings of Qac, cardiac output, and arterial blood pressure measured early and late during haemodialysis were obtained in 11 patients for a period o...
متن کاملExceptional Cases More may be less: increasing extracorporeal blood flow in an axillary arterio-arterial access decreases effective clearance
Axillary arterio-arterial graft interposition has been described as a reasonable haemodialysis access in selected patients. In a patient with this unusual access, we measured and calculated effective clearance at different extracorporeal blood flows (Qb). Effective clearance increased with increasing blood flow and reached a maximum at a Qb of ∼200 mL/min but then decreased when Qb was increase...
متن کاملValidation in the sheep of an ultrasound velocity dilution technique for haemodialysis graft flow.
BACKGROUND A simple, rapid, inexpensive method for measuring the flow in a patient's vascular access would permit routine monitoring during haemodialysis, and hence provide information of access graft deterioration sufficiently early to increase the success of minimally invasive remedial procedures. This paper reports the validation of such a method in animals. METHODS A PTFE graft was implan...
متن کاملIn vivo validation of a thermodilution method to determine regional left ventricular blood flow in patients with coronary disease.
Several methods have been used to measure left ventricular regional blood flow in humans. However, limitations and lack of validation in patients are major problems. A continuous thermodilution technique to measure regional left ventricular blood flow in patients with coronary disease was validated in vivo. This technique permits simultaneous assessment of venous blood flow draining predominant...
متن کاملاندازه گیری رسیرکولاسیون در فیستول شریانی ـ وریدی در بیماران همودیالیز
Hemodialysis access recirculation occurs when dialyzed blood returning through the venous needle reenters the extracorporeal circuit through the arterial needle rather than returning to the systemic circulation. It is important to meausre hemodialysis access recirculation for two reasons: The reentry of dialyzed blood into the extracorporeal circuite reduces solute &n...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Nephrology, dialysis, transplantation : official publication of the European Dialysis and Transplant Association - European Renal Association
دوره 14 2 شماره
صفحات -
تاریخ انتشار 1999