Refractive error, axial length and anterior chamber depth of the eye in British adults: the EPIC-Norfolk Eye Study.
نویسندگان
چکیده
PURPOSE To describe the distribution, and demographic and socioeconomic correlates of refractive error and related ocular biometry in an older British population. METHODS Refractive error was measured using an auto-refractor without cycloplegia. Pseudophakic individuals and those who had undergone refractive surgery were excluded from analysis. Axial length and anterior chamber depth were measured using partial coherence laser interferometry. Occupation category and highest educational achievement were recorded. RESULTS Biometric data were available for 2519 people (1090 men, 1429 women; 93.2% of all participants) aged 48 to 88 years. Refractive data were available for both eyes in 2210 bilaterally phakic participants. Among phakic individuals, axial length of the eye was strongly inversely correlated with refractive error in both men and women (p<0.001). Axial length of the eye was strongly, independently related to height, weight and social class, but most strongly related to educational achievement. In contrast, anterior chamber depth varied with age and sex, but not with socioeconomic status. There was a significant inverse association between anterior chamber depth and refraction in women (p<0.001) but not in men (p=0.495). CONCLUSION Refractive error in this predominantly white older UK population was associated with axial biometry and sociodemographic characteristics. Educational status was the strongest determinant of axial length.
منابع مشابه
Relationship between central corneal thickness, refractive error, corneal curvature, anterior chamber depth and axial length.
BACKGROUND To determine the relationship between central corneal thickness (CCT), refractive error, corneal curvature, anterior chamber depth and axial length in normal Taiwanese Chinese adults. METHODS Five hundred normal Taiwanese Chinese patients aged 40-80 years were recruited for the study. Measurement procedures included CCT, refractive error, corneal curvature, anterior chamber depth a...
متن کاملCrystalline lens power and refractive error.
PURPOSE To study the relationships between the refractive power of the crystalline lens, overall refractive error of the eye, and degree of nuclear cataract. METHODS All phakic participants of the population-based Central India Eye and Medical Study with an age of 50+ years were included. Calculation of the refractive lens power was based on distance noncycloplegic refractive error, corneal r...
متن کاملThe Correlation between Glucose and Lipid Biomarkers Variations with biometric characteristics and Intraocular Pressure Changes during Ramadan Fasting
Introduction: The aim of present study was to assess the correlation between glucose and lipid biomarkers variations with biometric characteristics and intraocular pressure changes following Ramadan fasting. Methods: A total of 100 healthy fasting volunteers were enrolled in the study. Of them, 89 subjects completed the study with respect to inclusion and exclusion criteria. Right eye ocular ax...
متن کاملThe Relationship between Crystalline Lens Power and Refractive Error in Older Chinese Adults: The Shanghai Eye Study
PURPOSE To report calculated crystalline lens power and describe the distribution of ocular biometry and its association with refractive error in older Chinese adults. METHODS Random clustering sampling was used to identify adults aged 50 years and above in Xuhui and Baoshan districts of Shanghai. Refraction was determined by subjective refraction that achieved the best corrected vision based...
متن کاملOcular biometry and determinants of refractive error in rural Myanmar: the Meiktila Eye Study.
OBJECTIVE To describe the ocular biometry and determinants of refractive error in an adult population in Myanmar. METHODS A cross-sectional, population-based survey of the inhabitants 40 years of age and over from villages in the Meiktila District was performed; 2481 eligible participants were identified, and 2076 participated in the study. Biometric components including axial length (AL), an...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- The British journal of ophthalmology
دوره 94 7 شماره
صفحات -
تاریخ انتشار 2010