Evaluation of the Ves-Matic Cube 200 erythrocyte sedimentation method: comparison with Westergren-based methods.

نویسندگان

  • Joyce Curvers
  • Jurgen Kooren
  • Maartje Laan
  • Edwin van Lierop
  • Daan van de Kerkhof
  • Volkher Scharnhorst
  • Martien Herruer
چکیده

The erythrocyte sedimentation rate (ESR) is still a widely used parameter for acute phase inflammation. Recently, new methods based on direct undiluted measurement of ESR in a standard EDTA tube have been developed. We evaluated the analytic performance of one of these new methods, the Ves-Matic Cube 200 (Diesse Diagnostica Senese, Siena, Italy), and compared it with several established Westergren-based diluted methods. The Ves-Matic Cube 200 showed a poor correlation (r = 0.83) with the International Council for Standardization in Haematology Westergren reference method, mainly caused by a considerable negative bias at low ESR levels. Moreover, a random bias was found at higher ESR levels that correlated with hematocrit levels, suggesting a differential influence of packed cell volume on the Ves-Matic Cube 200 results compared with Westergren results. We conclude that the Ves-Matic Cube 200 method is not interchangeable with Westergren-based diluted methods and generates ESR results that are too deviant to be clinically acceptable.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Evaluation of Ves-Matic Cube 200--an automated system for the measurement of the erythrocyte sedimentation rate.

Ves-Matic Cube 200 is fully automated analyzer that performs erythrocyte sedimentation rate (ESR) measurement using the standard ethylenediaminetetraacetic acid blood sample tube, thus markedly reducing the analytical time and avoiding the need for an extra blood sample. The aim of this study was to assess the automatic Ves-Matic Cube 200 system for the measurement of ESR in comparison with the...

متن کامل

Assessment of Diesse Ves-matic automated system for measuring erythrocyte sedimentation rate.

Measurement of the erythrocyte sedimentation rate (ESR) using a closed tube system reduces the biohazard risk to laboratory staff. The Diesse Ves-matic system offers manual or vacuum collection of blood into plastic tubes, automated mixing of the sample, and automated reading of the end point after 20 minutes of sedimentation. This system was compared with the 1977 Westergren ESR method of the ...

متن کامل

Validation of the Diesse Mini-Ves erythrocyte sedimentation rate (ESR) analyzer using the Westergren ESR method in patients with systemic inflammatory conditions.

The Diesse Mini-Ves (DMV) erythrocyte sedimentation rate (ESR) analyzer was designed to improve efficiency in determining the ESR. We compared the Westergren ESR method with the 4-sample DMV ESR analyzer for performance and clinical correlation. This prospective observational study, conducted at a 450-bed tertiary medical center, evaluated 291 paired samples from subjects with various systemic ...

متن کامل

A Comparison Between the StaRRsed Auto-Compact Erythrocyte Sedimentation Rate Instrument and the Westergren Method

BACKGROUND The Westergren method is the golden standard for measuring erythrocyte sedimentation rate (ESR). All ESR methods should agree with the standardized method of the International Council for Standardization in Hematology (ICSH). Citrate samples are commonly used for ESR. This extra sample adds costs and can be inconvenient for the patient. Therefore, some new automated ESR analyzers use...

متن کامل

Comparative study between Westergren and modified microhaematocrit method for determination for erythrocyte sedimentation rate

To compare between standard Westergren and modified microhaematocrit method for determination for erythrocyte sedimentation rate Study design: A laboratory method comparative study. Subjects: blood samples from 80 individual subjects. For each subject, two methods for erythrocyte sedimentation rate determination were performed. The first method was the Westergren method as a standard method and...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • American journal of clinical pathology

دوره 134 4  شماره 

صفحات  -

تاریخ انتشار 2010