Mitral replacement: clinical experience with a ball-valve prosthesis. Twenty-five years later.

نویسندگان

  • A Cobanoglu
  • G L Grunkemeier
  • G M Aru
  • C L McKinley
  • A Starr
چکیده

The purpose of this report is to review the results of mitral valve replacement since a first report in the Annals of Surgery in 1961, in order to determine the relative importance of new valve designs versus other surgical variables. The continued use of the silastic ball valve in its 1966 configuration (Model 6120), by providing a comparative data base for other new prosthetic valves, allows this analysis. For a valid comparison with the tilting disc (Bjork-Shiley) and the porcine (Hancock and Carpentier-Edwards) valves, only results with the silastic ball valves implanted during comparable time frames should be used. (Formula: see text) Thus, there are no significant differences in the results obtained with the silastic ball valve in time frames comparable to other contemporary valves introduced in the early 1970s. Improved results, therefore, must be non-prosthetic valve related.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Double Valve Replacement (Mitral and Aortic) for Rheumatic Heart Disease: A 20-year experience with 300 patients.

Introduction: Rheumatic heart disease still remains one of the leading causes of congestive heart failure and death owing to valvular pathologies, in developing countries. Valve replacement still remains the treatment of choice in such patients.The aim of this study wasto analyze the postoperative outcome of  double valve replacement (Mitral and Aortic ) in patients of rheumatic heart disease. ...

متن کامل

Twenty-five year experience with the St. Jude medical mechanical valve prosthesis.

BACKGROUND We evaluated all adult St. Jude mechanical valve recipients at our institution since the initial implant in January 1979 and now present our 25-year experience. METHODS Nine hundred forty-five valve recipients were followed prospectively at 12-month intervals from January 1979 to December 2007. RESULTS Operative mortality was 3% in the aortic valve recipients and 5% in the mitral...

متن کامل

Successful Use of Two Thrombolytic Drugs in Prosthetic Mitral and Aortic Valve Thrombosis

Introduction: Prosthetic valve thrombosis is a rare and severe complication of valve replacement, most often encountered with a mechanical prosthesis. The significant morbidity and mortality associated with this condition warrant rapid diagnostic evaluation. Although surgery is the first-line therapy in symptomatic obstructive mechanical valve thrombosis, thrombolytic therapy has been used as a...

متن کامل

Aortic Replacement

COMPLETE valvular replacement is the only feasible method for treatment of many cases of aortic valvular disease. While the long-term results will not be known for some time, the prognosis without operation, in carefully selected patients, is so poor as to justify this approach. Our total experience, consisting of a group of 16 such patients undergoing aortic replacement with the ballvalve pros...

متن کامل

Replacement of an aortic Starr-Edwards ball valve prosthesis 28 years after implantation.

A 53-year-old woman who had undergone aortic valve replacement with a Starr-Edwards (S-E) valve (Model 1260) and open mitral commissurotomy 28 years previously was hospitalized with cardiac failure. Echocardiography showed mitral stenosis, mitral regurgitation, and a normally functioning S-E prosthesis. At reoperation, the mitral and aortic valves were replaced with St Jude bileaflet mechanical...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Annals of surgery

دوره 202 3  شماره 

صفحات  -

تاریخ انتشار 1961