Automatic Adaptive Inverse Planning Optimization for H&N Cancer Radiotherapy
نویسندگان
چکیده
An iterative method was developed for the adaptive inverse planning automation. The expected treatment dose in organs of interest constructed using the previous and on going treatment plans, and daily CBCT images was utilized to setup an initial criteria for each organ in the objective function. Following the initial inverse planning optimization, the achieved objective value was used to modify the previous criteria in the objective with respect to a pre-determined formulation, and then a new inverse planning optimization was repeated accordingly. The iteration was stopped if there was no clear improvement in the objective. Figure 1 shows the flow chart for the automatic plan algorithm.
منابع مشابه
Optimization of clinical target volume delineation using magnetic resonance spectroscopic imaging (MRSI) in 3D conformal radiotherapy of prostate cancer
Background: For the purpose of individual clinical target volume assessment in radiotherapy of prostate cancer, MRSI was used as a molecular imaging modality with MRI and CT images. Materials and Methods: The images of 20 prostate cancer patients were used in this study. The MR and MRSI images were registered with CT ones using non-rigid registration technique. The CT based planning (BP), CT/MR...
متن کاملSparse Solution for the Intensity-Modulated Radiotherapy Problem Using Conic Programming
We address the problem of planning an effective IMRT (Intensity Modulated Radiotherapy) treatment for cancer. IMRT is a modern method of radiotherapy. It irradiates cancerous tissues by administering lethal dose of radiation to those cells, while sparing the healthy tissues. This method’s greatest advantage is the large degree of freedom which it allows the treatment planning, but it is also it...
متن کاملTreatment Planning Considerations Using IMRT
Introduction ...........................................................103 IMRT or 3DCRT? ...................................................105 The MSKCC IMRT Planning Process....................107 Patient Selection • Patient Simulation And Structure Localization • Selection Of Beam Energy, Number, And Direction • Optimization • Conversion Of Intensity Profiles To Leaf Motion • Forward Dose ...
متن کاملAn Overview on the Clinical Application of Radiobiological Modeling in Radiation Therapy of Cancer
Submit Manuscript | http://medcraveonline.com Abbreviations: TCP: Tumor Control Probability; NTCP: Normal Tissue Control Probability; LKB: Lyman Kutcher Burman; IGRT: Image Guided Radiation Therapy; IMRT: Intensity Modulated Radiation Therapy; SIB-IMRT: Simultaneous Integrated BoostIMRT; VMAT: Volumetric Modulated Arc Therapy; DA: Double Arc; SA: Single Arc; HT: Helical Tomotherapy; IFP: Improv...
متن کاملDetermining rectal dose through cervix cancer radiotherapy by 9 MV photon beam using TLD and XR type T GAFCHROMIC® Film
Background: The goals of the present research were to investigate the rectal dose during four chosen techniques of cervical cancer radiotherapy and to examine how accurately the treatment planning represents dose measurements, and it’s practicality for routine use as well as, to determine the homogeneity of dose in tumor volume. Materials and Methods: The study was carried out using a Nepton 10...
متن کامل