Simultaneous monitoring of static and dynamic intracranial pressure parameters from two separate sensors in patients with cerebral bleeds: comparison of findings
نویسندگان
چکیده
BACKGROUND We recently reported that in an experimental setting the zero pressure level of solid intracranial pressure (ICP) sensors can be altered by electrostatics discharges. Changes in the zero pressure level would alter the ICP level (mean ICP); whether spontaneous changes in mean ICP happen in clinical settings is not known. This can be addressed by comparing the ICP parameters level and waveform of simultaneous ICP signals. To this end, we retrieved our recordings in patients with cerebral bleeds wherein the ICP had been recorded simultaneously from two different sensors. MATERIALS AND METHODS During a time period of 10 years, 17 patients with cerebral bleeds were monitored with two ICP sensors simultaneously; sensor 1 was always a solid sensor while Sensor 2 was a solid -, a fluid - or an air-pouch sensor. The simultaneous signals were analyzed with automatic identification of the cardiac induced ICP waves. The output was determined in consecutive 6-s time windows, both with regard to the static parameter mean ICP and the dynamic parameters (mean wave amplitude, MWA, and mean wave rise time, MWRT). Differences in mean ICP, MWA and MWRT between the two sensors were determined. Transfer functions between the sensors were determined to evaluate how sensors reproduce the ICP waveform. RESULTS Comparing findings in two solid sensors disclosed major differences in mean ICP in 2 of 5 patients (40%), despite marginal differences in MWA, MWRT, and linear phase magnitude and phase. Qualitative assessment of trend plots of mean ICP and MWA revealed shifts and drifts of mean ICP in the clinical setting. The transfer function analysis comparing the solid sensor with either the fluid or air-pouch sensors revealed more variable transfer function magnitude and greater differences in the ICP waveform derived indices. CONCLUSIONS Simultaneous monitoring of ICP using two solid sensors may show marked differences in static ICP but close to identity in dynamic ICP waveforms. This indicates that shifts in ICP baseline pressure (sensor zero level) occur clinically; trend plots of the ICP parameters also confirm this. Solid sensors are superior to fluid - and air pouch sensors when evaluating the dynamic ICP parameters.
منابع مشابه
An intracranial pressure-derived index monitored simultaneously from two separate sensors in patients with cerebral bleeds: comparison of findings
BACKGROUND In an attempt to characterize the intracranial pressure-volume compensatory reserve capacity, the correlation coefficient (R) between the ICP wave amplitude (A) and the ICP (P) level (RAP) has been applied in the surveillance of neurosurgical patients. However, as the ICP level may become altered by electrostatic discharges, human factors, technical factors and technology issues rela...
متن کاملComparison of Center of Pressure and time to Stabilization in students with and without Hyperlordosis
Objective: According to importance of balance in daily routines and sports activities, it is necessary to evaluate the balance of the body from different angles. Therefore, the aim of this study was to Comparison of Center of Pressure and time to Stabilization in students with and without Hyperlordosis. Methods: In this study, 30 female students of Tehran's middle school with a range of 14-15 ...
متن کاملبررسی بیماری ACL با استفاده از ابزار سنجش توزیع فشار کف پا به صورت بیسیم
Received: 14 Apr, 2013 Accepted: 13 Jun, 2013Abstract Background & Aims: One of the methods for abnormalities motion is the gait analysis using the analysis of plantar pressure distribution. This method is not only very costly but also it needs the adequate space to locate the equipment in some cases connection of the accessories to the patient leads to the limitation of the patient’s motions....
متن کاملMULTIOBJECTIVE OPTIMIZATION OF SENSOR PLACEMENT IN WATER DISTRIBUTION NETWORKS DUAL USE BENEFIT APPROACH
Location and types of sensors may be integrated for simultaneous achievement of water security goals and other water utility objectives, such as regulatory monitoring requirements. Complying with the recent recommendations on dual benefits of sensors, this study addresses the optimal location of these types of sensors in a multipurpose approach. The study presents two mathematical models for ...
متن کاملCerebral Angiographic Findings in Non-Traumatic Intracranial Hemorrhage: A Single Center Experience in the West of Iran
Background and Aim: This study aimed at analyzing the demographic characteristics of the patients with non-traumatic intracranial hemorrhage, their angiographic results and the correlation between computed tomography (CT) scan and angiography findings. Methods and Materials/Patients: In a descriptive study, we retrospectively reviewed the records of the patients with non-traumatic intracranial...
متن کامل