The accuracy of single emulsion radiographic film in linear measurement of spiral tomography
نویسندگان
چکیده
BACKGROUND Conventional tomography used for evaluation of the small areas of the jaws provides acceptable information. It has some advantages of availability, less radiation dose and cost in comparison to computed tomography (CT) and cone beam CT. Double emulsion film usually used for taking tomograms requires less exposure than single emulsion film; on the other hand, the latter provides more sharpness and spatial resolution. The aim of this study was to compare diagnostic accuracy of these two kinds of films in the spiral tomography. MATERIALS AND METHODS In an experimental study, 20 lines (10 lines anterior and 10 lines posterior to the mental foramen) were selected on two dry human mandibles and tomographic images were taken from each line with and without metal marker by single and double emulsion films. For quantitative assessment, the mandibular width and length was identified and measured on 80obtained tomograms. Afterwards, the mandibles were sectioned on each line and their actual width and height were measured. For each line, the data of tomograms were subtracted from gold standard as measurement error. These errors were divided into three groups: Greater than +1 mm, between +1 mm and -1 mm and less than -1 mm. Obtained data were analyzed by Pearson Chi-square test (α=0/05). RESULTS There was no significant difference between the single and double emulsion films, with and without markers in the measurement of both height and width of mandible (P > 0.05). CONCLUSION The single emulsion film is not recommended to be used for taking the spiral tomogram.
منابع مشابه
توموگرافی خطی با فیلم و Photostimulable Phosphor Plate در طرح درمان ایمپلنت در مندیبل
Background and Aims: Radiographic examination prior to implant placement is often complemented with tomography for location of vital anatomic structures and evaluation of bone volume. The aim of this study was to evaluate the accuracy of Photostimulable Phosphor Plate system with that of conventional film-screen in mandibular pre-implant linear tomography Materials and Methods: In this test eva...
متن کاملAccuracy of mandibular vertical linear measurement in panoramic and tomography images
Introduction: The measurement precision of jaw is important for surgery or installing implants. Preimplant radiographs are important part of clinical evaluations before implant surgery. For choosing location, we should consider the important anatomical structures like mental foramen, inferior alveolar canal, nasal cavity and maxillary sinus.It is important to know the measurement accuracy of ra...
متن کاملComparing the Accuracy of Cone Beam Computed Tomography,Digital Intraoral Radiography and Conventional Intraoral Radiography in the Measurement of Periodontal Bone Defects
Background and Aim: Cone beam computed tomography (CBCT) produces high-quality data in periodontal diagnosis and treatment planning. The aim of this study was to compare the accuracy of CBCT with intraoral digital and conventional radiography in the measurement of periodontal bone defects. Methods and Materials: In this diagnostic research, two hundred and eighteen artificial osseous d...
متن کاملبررسی دقت توموگرافی خطی در تعیین محل حفره بینی و سینوس ماگزیلاری1
Background and Aim: Accurate measurement of bone height and width is essential prior to dental implant placement. The method of surgery as well as, the type and size of implants are determined according to dimensions of the residual bone. The purpose of this study was to evaluate the accuracy of linear tomography in localization of the floor of nasal fossa and maxillary sinus, and to determine ...
متن کاملدقت رادیوگرافی پانورامیک و توموگرافی خطی در تعیین محل کانال مندیبولار
Background and Aim: Accurate bone measurements are essential to determine the optimal size and length of dental implants. The magnification factor of radiographic images may vary with the imaging technique used. The purpose of this study was to compare the accuracy of linear tomography and panoramic radiography in vertical measurements, as well as the accuracy of linear tomography in mandibular...
متن کامل