An X-ray polarimeter for hard X-ray optics

نویسندگان

  • Fabio Muleri
  • Ronaldo Bellazzini
  • Enrico Costa
  • Paolo Soffitta
  • Francesco Lazzarotto
  • Marco Feroci
  • Luigi Pacciani
  • Alda Rubini
  • Ennio Morelli
  • Luca Baldini
  • Francesco Bitti
  • Alessandro Brez
  • Francesco Cavalca
  • Luca Latronico
  • Marco Maria Massai
  • Nicola Omodei
  • Michele Pinchera
  • Carmelo Sgró
  • Gloria Spandre
  • Giorgio Matt
  • Giuseppe Cesare Perola
  • Oberto Citterio
  • Giovanni Pareschi
  • Vincenzo Cotroneo
  • Daniele Spiga
  • Rodolfo Canestrari
چکیده

Development of multi-layer optics makes feasible the use of X-ray telescope at energy up to 60-80 keV: in this paper we discuss the extension of photoelectric polarimeter based on Micro Pattern Gas Chamber to high energy X-rays. We calculated the sensitivity with Neon and Argon based mixtures at high pressure with thick absorption gap: placing the MPGC at focus of a next generation multi-layer optics, galatic and extragalactic X-ray polarimetry can be done up till 30 keV.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

A polarimeter for IXO

The X-ray POLarimeter (XPOL) is an instrument that will fly on-board the International X-ray Observatory (IXO). We will describe the XPOL setup in IXO and we will compare the IXO requirements with the actual prototype performance. The environmental tests performed on the XPOL prototype (thermo-vacuum, vibration and heavy ions irradiation) show that this technology is ready for a space applicati...

متن کامل

مقایسه گسیل یونی و پرتوی ایکس سخت بین نیتروژن و آرگون در دستگاه پلاسمای کانونی نوع مدر

In this study, some characteristics of a Mather type Plasma Focus (PF) device such as a discharge current, pinch time, ion flux and hard x-ray intensity has been investigated simultaneously in argon and nitrogen gases separately for various operating gas pressures and charging voltages of capacitor bank. It was observed that pinch phenomena was energy and pressure dependent in current sheath as...

متن کامل

Optimum driving a Z-pinch for soft X-Ray lasers

A capillary plasma z-pinch as an alternative active medium of soft X-Ray lasers was studied experimentally and theoretically. The theoretical analysis was based on the self consistent solution of the so called “snow plow” model. The dynamics of pinched plasma is determined by the capillary parameters and by the time dependence of electrical current passing through it. The current time dependenc...

متن کامل

A Soft X-ray Polarimeter Designed for Broad-band X-ray Telescopes

A novel approach for measuring linear X-ray polarization over a broad-band using conventional imaging optics and cameras is described. A new type of high efficiency grating, called the critical angle transmission grating is used to disperse soft X-rays radially from the telescope axis. A set of multilayer-coated paraboloids re-image the dispersed X-rays to rings in the focal plane. The intensit...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره   شماره 

صفحات  -

تاریخ انتشار 2006