Effects of the HeartMate II continuous-flow left ventricular assist device on right ventricular function.
نویسندگان
چکیده
BACKGROUND Continuous-flow devices have become the standard of care for mechanical circulatory support for end-stage heart failure patients because of improved survival and durability. The effects of these devices, such as the HeartMate II (HMII) left ventricular assist device (LVAD), on right ventricular (RV) function have not been evaluated in detail. This study evaluated the incidence of RV failure, alterations in RV function, severity of tricuspid regurgitation (TR), and cardiac hemodynamics after HMII implantation. METHODS Echocardiograms (n = 22) and right heart catheterizations (n = 40) were performed before and after 4 to 6 months of HMII support in 40 bridge-to-transplant patients. Right heart failure was defined as the requirement for inotropes and/or nitric oxide requirement after LVAD implantation for >14 days or the need for right-sided mechanical circulatory support. RESULTS Overall, RV failure after HMII implantation occurred in 2 of 40 patients (5%). Significant improvements occurred in cardiac index, with reductions in right atrial pressure, RV stroke work index, tricuspid annular motion, mean pulmonary artery pressure, and pulmonary vascular resistance after HMII support. There was a trend towards reduction in TR after LVAD support (p = 0.075). CONCLUSIONS The incidence of RV failure after support with continuous-flow devices such as the HMII is low. The favorable effects of the HMII on cardiac hemodynamics result in improved RV function, improved right- and left-sided hemodynamic profiles, and a reduction in TR severity. These findings may have important implications for LVAD patients needing longer-term support.
منابع مشابه
Right heart dysfunction after left ventricular assist device implantation: a comparison of the pulsatile HeartMate I and axial-flow HeartMate II devices.
BACKGROUND Right heart dysfunction confers significant morbidity and mortality after left ventricular assist device implantation and historically occurs in as many as a third of patients. It is unknown whether newer axial flow pumps have a different impact on postimplant right heart dysfunction. We compared the incidence of right heart dysfunction after implantation of the pulsatile HeartMate I...
متن کاملRight ventricular failure in patients with the HeartMate II continuous-flow left ventricular assist device: incidence, risk factors, and effect on outcomes.
OBJECTIVE The aim of this study was to evaluate the incidence, risk factors, and effect on outcomes of right ventricular failure in a large population of patients implanted with continuous-flow left ventricular assist devices. METHODS Patients (n = 484) enrolled in the HeartMate II left ventricular assist device (Thoratec, Pleasanton, Calif) bridge-to-transplantation clinical trial were exami...
متن کاملRenal and hepatic function improve in advanced heart failure patients during continuous-flow support with the HeartMate II left ventricular assist device.
BACKGROUND The effects of continuous blood flow and reduced pulsatility on major organ function have not been studied in detail. METHODS AND RESULTS We evaluated renal (creatinine and blood urea nitrogen) and hepatic (aspartate transaminase, alanine transaminase, and total bilirubin) function in 309 (235 male, 74 female) advanced heart failure patients who had been supported with the HeartMat...
متن کاملEditorial comment: Adverse events in long-term ventricular assist device therapy.
the higher risk of developing a thrombosis anyway. In conclusion, compared with the other study results, our data suggest that a notably mild anticoagulation protocol does not increase the risk of severe thrombo-embolic events in the early and late postoperative period after the implantation of the HM II CW LVAD. Furthermore, this mild regime is helpful in reducing the still unacceptably high i...
متن کاملHemodynamic and exercise performance with pulsatile and continuous-flow left ventricular assist devices.
BACKGROUND Continuous-flow rotary pumps with axial design are increasingly used for left ventricular assist support. The efficacy of this design compared with pulsatile, volume displacement pumps, with respect to characteristics of left ventricular unloading, and exercise performance remains largely unstudied. METHODS AND RESULTS Thirty-four patients undergoing implantation with a pulsatile, ...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- The Journal of heart and lung transplantation : the official publication of the International Society for Heart Transplantation
دوره 29 2 شماره
صفحات -
تاریخ انتشار 2010