Physiological vortices in the sinuses of Valsalva: An in vitro approach for bio-prosthetic valves

نویسندگان

  • Riccardo Toninato
  • Jacob Salmon
  • Francesca Maria Susin
  • Andrea Ducci
  • Gaetano Burriesci
چکیده

PURPOSE The physiological flow dynamics within the Valsalva sinuses, in terms of global and local parameters, are still not fully understood. This study attempts to identify the physiological conditions as closely as possible, and to give an explanation of the different and sometime contradictory results in literature. METHODS An in vitro approach was implemented for testing porcine bio-prosthetic valves operating within different aortic root configurations. All tests were performed on a pulse duplicator, under physiological pressure and flow conditions. The fluid dynamics established in the various cases were analysed by means of 2D Particle Image Velocimetry, and related with the achieved hydrodynamic performance. RESULTS Each configuration is associated with substantially different flow dynamics, which significantly affects the valve performance. The configuration most closely replicating healthy native anatomy was characterised by the best hemodynamic performance, and any mismatch in size and position between the valve and the root produced substantial modification of the fluid dynamics downstream of the valve, hindering the hydrodynamic performance of the system. The worst conditions were observed for a configuration characterised by the total absence of the Valsalva sinuses. CONCLUSION This study provides an explanation for the different vortical structures described in the literature downstream of bioprosthetic valves, enlightening the experimental complications in valve testing. Most importantly, the results clearly identify the fluid mechanisms promoted by the Valsalva sinuses to enhance the ejection and closing phases, and this study exposes the importance of an optimal integration of the valve and root, to operate as a single system.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Transcatheter aortic valves produce unphysiological flows which may contribute to thromboembolic events: An in-vitro study

PURPOSE Transcatheter aortic valve implantation (TAVI) has been associated with large incidence of ischemic events, whose sources are still unclear. In fact, sub-acute complications cannot be directly related to the severity of the calcification in the host tissues, nor with catheter manipulation during the implant. A potential cause could be local flow perturbations introduced by the implantat...

متن کامل

Pregnancy Outcome with Intracytoplasmic Sperm Injection Method in a Woman with Prosthetic Heart Valves

There is an increased risk of thromboembolism, anticoagulant-related hemorrhage, fetal-wastage and congestive cardiac failure in pregnant women with mechanical heart valves. In order to have a good outcome, the care of such patients must necessarily be multidisciplinary and in a well- equipped centre with adequate support services .One such patient who had mechanical mitral and aortic valves re...

متن کامل

Fluid Mechanics of Deformable Aortic Prostheses

The simultaneous replacement of a diseased aortic valve, aortic root and ascending aorta with a composite graft equipped with a prosthetic valve is a nowadays standard surgical approach, known as the Bentall procedure: the Valsalva sinuses of the aortic root are sacrificed and the coronary arteries are reconnected directly to the graft. In practice, two different composite–material prostheses a...

متن کامل

The anatomy of the sinus of Valsalva.

The anatomy of the aortic root has been studied in different species, and common structural features of importance have been detailed. The findings confirm the universal presence of a wellmarked ridge limiting the distal extent of the aortic sinuses. Redefining the sinuses in this way shows that normally the coronary ostia lie within the sinus proximal to the ridge and it appears that their pos...

متن کامل

Preassembled stentless valved-conduit for the replacement of the ascending aorta and aortic root.

Here we report the early clinical results of a new preassembled stentless valved-conduit incorporating artificial sinuses of Valsalva (BioValsalva). This new composite conduit incorporates a stentless porcine aortic valve (Elan, Vascutek Terumo, UK) suspended within a triple-layered vascular conduit (Triplex, Vascutek Terumo, UK) constructed with sinuses of Valsalva. Between December 2006 and J...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره 49  شماره 

صفحات  -

تاریخ انتشار 2016