Islanding detection of synchronous distributed generators

نویسندگان

  • A. Etxegarai
  • I. Zamora
  • P. Eguia
  • L. Valverde
چکیده

This paper analyses the performance of local passive islanding detection methods for synchronous distributed generators, under different grid and load scenarios. These methods monitor electrical parameters at the interconnection point of a distributed generator and detect island situation whenever these parameters change correspondingly. Lately, islanding detection research has been focused on inverter based systems. But synchronous generators still pose a challenge for study. With this aim, a low voltage distribution network with embedded synchronous generators has been modelled. The performance of frequency and rate-of-change-of-frequency relays have been evaluated, analysing the influence of power mismatch and generator characteristics on the islanding and also avoid false operation.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

An Intelligent Anti-Islanding Scheme for Synchronous-Based Distributed Generation Using Reduced-Noise Morphological Gradient

This paper presents a pattern recognition-based scheme for detection of islanding conditions in synchronous- based distributed generation (DG) systems. The main idea behind the proposed scheme is the use of spatial features of system parameters such as the frequency, magnitude of positive sequence voltage, etc. In this study, the system parameters sampled at the point of common coupling (PCC) w...

متن کامل

An Integrated Passive Islanding Detection Method for Distributed Generators

This study proposes a new islanding detection method for use of grid-interconnected distributed generators (DG). The method is based on two indices: the rate of change of frequency (ROCOF) and the rate of change of voltage (ROCOV). When a DG is grid-interconnected, the ROCOF and ROCOV are lower than the threshold value. In contrast, as an islanding occurs, the ROCOF or ROCOV become much higher ...

متن کامل

Islanding Detection of Synchronous Machine-Based DGs using Average Frequency Based Index

Identification of intentional and unintentional islanding situations of dispersed generators (DGs) is one of the most important protection concerns in power systems. Considering safety and reliability problems of distribution networks, an exact diagnosis index is required to discriminate the loss of the main network from the existing parallel operation. Hence, this paper introduces a new island...

متن کامل

A Novel Passive Method for Islanding Detection in Microgrids

Integration of distributed generations (DGs) in power grids is expected to play an essential role in the infrastructure and market of electrical power systems. Microgrids are small energy systems, capable of balancing captive supply and requesting resources to retain stable service within a specific boundary. Microgrids can operate in grid-connected or islanding modes. Effective islanding detec...

متن کامل

Accidental Islanding of Distribution Systems with Multiple Distributed Generation Units of Various Technologies

The system response to accidental islanding and effect on anti-islanding detection of distribution feeders with multiple distributed generation (DG) technologies (synchronous machine and inverterbased units) is one major utility concern associated with increasing penetration of DG. Studies have been conducted to evaluate the performance of anti-islanding detection through use of conventional vo...