Outcomes of Charnley total hip arthroplasty using improved cementing with so-called second- and third-generation techniques

نویسندگان

  • Shiro Hirose
  • Hiromi Otsuka
  • Takkan Morishima
  • Keiji Sato
چکیده

BACKGROUND Techniques of cemented total hip arthroplasty have developed over time. We present the outcomes of Charnley total hip arthroplasty performed using improved second- and third-generation cementing techniques. METHODS We reviewed the radiologic results of 91 Charnley total hip arthroplasties performed using second- and third-generation cementing techniques. Second-generation techniques involved making multiple anchor holes, a double-cementing method on the acetabular side and an intramedullary plug, and retrograde filling with a cement gun on the femoral side in 57 hips. Third-generation techniques involved additional vacuum mixing and cement pressurization in 34 hips. RESULTS Joint survival rates at 20 years when using second-generation techniques were 89% for the socket and 94% for the stem with aseptic loosening as the end point; the survival rates at 10 years when using third-generation techniques were 97 and 100%, respectively. According to our radiographic evaluation system for the clear zone at 5 years, there was less clear zone in the acetabular side with the third-generation techniques than with second-generation techniques. In the femoral side, there was very little development of the clear zone, but the difference between generations was not significant. CONCLUSIONS Second- and third-generation cementing techniques showed excellent survivorship. The clear zone scores at 5 years indicated that third-generation techniques were effective, especially in the acetabular side, and may produce better long-term results than second-generation techniques.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Primary Charnley total hip arthroplasty for congenital dysplasia: effect of improved techniques of cementing.

We performed Charnley total hip arthroplasties on 64 patients (71 hips) between 1976 and 1984 for moderate congenital acetabular dysplasia in which a superolateral cement thickness of less than 20 mm was expected when the cup was placed in the true acetabulum at an angle of 45 degrees. Of these, 59 hips were examined 10 to 17 years after operation; 37 (group A) had been operated on between 1976...

متن کامل

The Charnley versus the Spectron hip prosthesis: clinical evaluation of a randomized, prospective study of 2 different hip implants.

Prospective, randomized studies must be performed when new surgical techniques or implants are evaluated. In this study, a new implant system was compared with the Charnley prosthesis, which over the years has been the most used hip implant in Sweden. Between 1985 and 1989, 410 hips were randomized to treatment with a Charnley or a Spectron total hip arthroplasty: 206 Charnley and 204 Spectron ...

متن کامل

Long-term comparison of Charnley and Stanmore design total hip replacements.

We reviewed the records of the long-term outcome of 208 Charnley and 982 Stanmore total hip replacements (THR) performed by or under the supervision of one surgeon from 1973 to 1987. The Stanmore implant had a better survival rate before revision at 14 years (86% to 79%, p = 0.004), but the difference only became apparent at ten years. The later Stanmore implants did better than the early ones ...

متن کامل

Charnley total hip arthroplasty with use of improved cementing techniques: a minimum twenty-year follow-up study.

BACKGROUND In total hip arthroplasty, techniques for cementing the femoral component have changed over time. The purpose of the present study was to determine whether a cementing technique that includes use of a distal cement plug and retrograde filling of the femoral canal affects the fixation of the femoral component at a minimum of twenty years after the operation. METHODS Between 1976 and...

متن کامل

Finite element analysis of the effect of cementing concepts on implant stability and cement fatigue failure

BACKGROUND AND PURPOSE Two contradictory cementing techniques (using an undersized stem versus a canal-filling stem) can both lead to excellent survival rates, a phenomenon known as the "French paradox". Furthermore, previous studies have indicated that the type of bone supporting the cement mantle may affect implant survival. To further evaluate the mechanical consequences of variations in cem...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:

دوره 17  شماره 

صفحات  -

تاریخ انتشار 2012