Local reference dose evaluation in conventional radiography examinations in Iran

نویسندگان

  • M. Shirin Shandiz
  • M.T. Bahreyni Toossi
  • S. Farsi
  • K. Yaghobi
چکیده

The goal of this study was to establish local diagnostic reference levels (LDRLs) for conventional radiography examinations in Sistan-Baluchestan province of Iran, using dose area product (DAP) measurements followed by a comparison with international dose levels. DAP factor evaluation was carried out at eight radiography rooms in six public and one private health-care centers. The study employed DAP, exposure, and demographic data (weight, age, height) for 1069 patients who presented for one of the 11 routine radiography examinations: chest (AP, PA, LAT), abdomen (AP), lumbar spine (AP, LAT), pelvis (AP), skull (AP/PA, LAT), and cervical spine (AP, LAT). The data were analyzed statistically and the minimum, median, mean, maximum, and third quartile DAP values were calculated. It was observed that LDRLs for chest PA (0.26 Gy.cm²) and chest LAT (0.66 Gy.cm²) projections were up to 136% and 113% higher, respectively, than their corresponding NRPB 2005 values. Other radiographic procedures had lower recommended reference doses compared with recently recommended national reference doses published in recent NRPB reports and other studies. Wide variations in DAP values and exposure parameters were observed for similar radiographic procedures between patients in different rooms and for different patients in the same room. These and other observations, such as poor radiographic techniques, high rate of radiographic reject/repeat, and lack of modern X-ray machines and equipment, show that the need to carry out quality assurance programs is critical in Iran.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Local-Reference Patient Dose Evaluation in Conventional Radiography Examinations in Mazandaran, Iran

Background:The most efficient application of ionizing radiation is serving medical purposes and using this radiation has caused people to learn that artificial sources of radiation exposure among these resources can be of highest exposure rate.  Objective: The present study is aimed at initially establishing a baseline for local-reference dose level in Mazandaran, Iran in 12 projections of the...

متن کامل

Patient effective dose evaluation for chest X-ray examination in three digital radiography centers

Background: The radiation doses resulting from diagnostic X-ray examinations are routinely measured in terms of entrance surface dose (ESD) and effective dose (ED). In this study, for the purpose of radiation protection, the radiation doses received from Digital chest X-ray examination were evaluated in terms of ESD and ED. Material and Methods: The ED was calculated by using the MCNP ...

متن کامل

Local-Reference Patient Dose Evaluation in Conventional Radiography Examinations in Mazandaran, Iran

BACKGROUND The most efficient application of ionizing radiation is serving medical purposes and using this radiation has caused people to learn that artificial sources of radiation exposure among these resources can be of highest exposure rate. OBIECTIVE The present study is aimed at initially establishing a baseline for local-reference dose level in Mazandaran, Iran in 12 projections of the ...

متن کامل

A survey of annual effective and genetically significant dose from conventional X-ray examinations in 10 counties in Khorasan province-Iran

Background: A study has been conducted to assess two useful radiation protection indices, the annual per-capita effective dose equivalent (AED) and the genetically significant dose (GSD), from conventional diagnostic radiography in 10 counties with more than 1,886,000 inhabitants in Khorasan province in Iran. Materials and Methods: The health centre authorities of Khorasan province were asked t...

متن کامل

Local Diagnostic Reference Levels for Common Pediatric X-Ray Examinations in Khorasan Razavi Province, Iran

Introduction Given the fact that children are more sensitive to radiation, compared to adults, special attention needs to be paid to radiation protection in pediatric radiology. Diagnostic reference level (DRL) has been defined to be employed as a practical tool for examining the overall performance of a radiological center in terms of patient dose among a series of similar equipments in an are...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره 15  شماره 

صفحات  -

تاریخ انتشار 2014