Liver Injury Assessment by Vetscan VS2 Analyzer and Most Frequently Used ALT/GTP Reagent.
نویسندگان
چکیده
BACKGROUND AND AIM Liver injury is estimated by serum alanine aminotransferases (ALT) levels in experimental animal models. Laboratories use various techniques to measure ALT levels including assay reagents and chemistry analyzers. VetScan VS2 (VS2) is widely used in veterinary clinics and research laboratories for highly reproducible, convenient and effective testing. Alternatively, ALT liquid reagent is used by laboratories to estimate liver injury in animal studies. The aim of this study was to perform comparative analyses of data obtained from these two assays in two different animal models. METHODS In this study, we used two different mouse models and compared the ALT levels measured using VetScan VS2 chemistry analyzer and ALT liquid reagent. Immunohistochemical analysis of hepatic tissue was also performed to document liver pathology. The first model is a high fat diet feeding model that results in a mild hepatic steatosis (fat accumulation in the liver) without elevation of ALT levels. For a severe liver injury model, we employed a hepatotoxin-induced liver injury model (carbon tetrachloride, CCl4), which leads to the development of hepatic fibrosis and very high ALT levels. RESULTS VetScan VS2 and ALT reagent gave different values of ALT for all animal groups. However, linear regression analysis showed a significantly high association between ALT levels obtained by VS2 and ALT liquid reagent in a high-fat feeding model with no liver injury. For the CCl4 induced liver injury model, serum dilution (5 and 10 times) was performed to obtain accurate results with ALT reagent. ALT levels acquired from both techniques showed a close association. Interestingly, this correlation was closer when serum was diluted 5 fold. CONCLUSION This study demonstrates that both methods give similar results when evaluating liver injury in animal studies. However, the serum dilution factor is critical for severe liver injury assessment when using ALT reagent and requires some optimization. In this regard, VetScan VS2 is easier to use and gives comparable results.
منابع مشابه
Evaluation of four hematology and a chemistry portable benchtop analyzers using non-human primate blood.
BACKGROUND Near patient testing (NPT) and point-of-care testing (POCT) using portable benchtop analyzers has become necessary in many areas of the medical community, including biocontainment. METHODS We evaluated the Beckman AcT diff, Abaxis Vetscan HMII (two instruments), Abbott Cell-Dyn 1800, and Abaxis Vetscan VS2 for within-run precision and correlation to central laboratory instruments u...
متن کاملComparison of blood aminotransferase methods for assessment of myopathy and hepatopathy in Florida manatees (Trichechus manatus latirostris).
Muscle injury is common in Florida manatees (Trichechus manatus latirostris). Plasma aspartate aminotransferase (AST) is frequently used to assess muscular damage in capture myopathy and traumatic injury. Therefore, accurate measurement of AST and alanine aminotransferase (ALT) is important in managed, free-ranging animals, as well as in those rehabilitating from injury. Activities of these enz...
متن کاملPROTECTIVE EFFECT OF PENTOXIFYLLINE ON LIVER INJURY INDUCED BY DEXAMETHASONE IN MICE
Background & Aims: Dexamethasone (Dex) is one of the most commonly used synthetic glucocorticoidbut its excessive intake can cause severe changes in liver function. The purpose of the study was to investigate the effect of pentoxifylline (PTX) on Dex-induced hepatic injury in mice. Materials & Methods: 24 adult male NMRI mice (36±2gr) were divided randomly into 4 groups (n=6): control, dexamet...
متن کاملThe preventive effect of atorvastatin on liver fibrosis in the bile duct ligation rats via antioxidant activity and down-regulation of Rac1 and NOX1
Objective(s): Atorvastatin is a cholesterol-lowering agent capable of inhibiting 3-hydroxy-3-methylglutaryl coenzyme A reductase. Recent studies have demonstrated new facets of atorvastatin, such as antioxidant and anti-fibrotic properties. We investigated the effect of atorvastatin on hepatic injury via the measurement of the antioxidant capacity and protein expressio...
متن کاملUse of a Portable Point-of-care (vetscan Vs2) Biochemical Analyzer for Measuring Plasma Biochemical Levels in Free-living Loggerhead Sea Turtles
The agreement of plasma biochemical values between a portable point-of-care analyzer and a veterinary diagnostic laboratory in wild caught loggerhead sea turtles (Caretta caretta) was tested. Banked plasma samples from presumptively healthy turtles collected for an on-going project that involves health assessments of sea turtles from the southeast coast of Florida were used for this study. Plas...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Gastroenterology & hepatology
دوره 4 4 شماره
صفحات -
تاریخ انتشار 2016