Polarimetric interferometer for nanoscale positioning applications.
نویسندگان
چکیده
We propose and demonstrate a displacement control method at the subnanometric scale based on a Michelson interferometer combined with a polarimeter and a phase-locked loop electronic board. Step by step displacements with a step value of 5 nm are presented. A repeatability of 0.47 nm is obtained from back and forth displacements over 1 mum range. We show that a residual ellipticity of less than 10 degrees on the polarization state leads to a positioning error of less than 1 nm. Such system could be used over millimeter range displacements in a controlled surrounding environment leading to numerous applications in nanometrology.
منابع مشابه
Extended-range fiber polarimetric strain sensor.
We describe a frequency-modulation technique that is applicable to two-beam interferometric systems illuminated by semiconductor diode lasers. The technique permits a determination of the optical path difference between the two arms of the interferometer and is used here to extend the range of a fiber polarimetric strain sensor by determining the order of the particular polarimetric fringe unde...
متن کاملSurface Desensitization of Polarimetric Waveguide Interferometers
Nonspecific surface binding of small protein molecules presents a major obstacle to surface biosensing techniques attempting to detect very low concentrations ( 1 pg/mm) of large biological objects such as cells and bacteria. A new method for selective desensitization of a polarimetric waveguide interferometer eliminates the background noise from nonspecific surface binding. We demonstrate the ...
متن کاملEvolvable Optical Systems and Their Applications
This paper describes evolvable optical systems and their applications developed at the National Institute of Advanced Industrial Science and Technology(AIST) in Japan. Three evolvable optical systems are described: (1) an evolvable ber alignment system, (2) an evolvable interferometer system, and (3) an evolvable femtosecond laser system. As the micron-meter resolution alignment of optical comp...
متن کاملReal-Time and Meter-Scale Absolute Distance Measurement by Frequency-Comb-Referenced Multi-Wavelength Interferometry
We report on a frequency-comb-referenced absolute interferometer which instantly measures long distance by integrating multi-wavelength interferometry with direct synthetic wavelength interferometry. The reported interferometer utilizes four different wavelengths, simultaneously calibrated to the frequency comb of a femtosecond laser, to implement subwavelength distance measurement, while direc...
متن کاملNanometer positioning control by a multiple-pass
High accuracy positioning systems in the nanometer range are needed for IC fabrication, research in microelectro-mechanical systems (MEMS) and nanotechnology. A linear encoder with sub-nanometer resolution is needed for such applications as large field x-ray lithography, large field scanning microscopes, x-ray microscopes, x-ray micromachining, etc. For a conventional laser interferometer the r...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- The Review of scientific instruments
دوره 79 12 شماره
صفحات -
تاریخ انتشار 2008