Hexagonal gradient scheme with RF spoiling improves spoiling performance for high‐flip‐angle fast gradient echo imaging
نویسندگان
چکیده
PURPOSE To present a framework in which time-varying gradients are applied with RF spoiling to reduce unwanted signal, particularly at high flip angles. METHODS A time-varying gradient spoiler scheme compatible with RF spoiling is defined, in which spoiler gradients cycle through the vertices of a hexagon, which we call hexagonal spoiling. The method is compared with a traditional constant spoiling gradient both in the transition to and in the steady state. Extended phase graph (EPG) simulations, phantom acquisitions, and in vivo images were used to assess the method. RESULTS Simulations, phantom and in vivo experiments showed that unwanted signal was markedly reduced by employing hexagonal spoiling, both in the transition to and in the steady state. For adipose tissue at 1.5 Tesla, the unwanted signal in the steady state with a 60 ° flip angle was reduced from 22% with constant spoiling to 2% with hexagonal spoiling. CONCLUSIONS A time-varying gradient spoiler scheme that works with RF spoiling, called "hexagonal spoiling," has been presented and found to offer improved spoiling over the traditional constant spoiling gradient. Magn Reson Med 77:1231-1237, 2017. © 2016 The Authors Magnetic Resonance in Medicine published by Wiley Periodicals, Inc. on behalf of International Society for Magnetic Resonance in Medicine. This is an open access article under the terms of the Creative Commons Attribution License, which permits use, distribution and reproduction in any medium, provided the original work is properly cited.
منابع مشابه
Improved Radial Spoiled Gradient Echo Imaging with Randomized RF Phases and Gradient Moments
Introduction Radiofrequency (RF) spoiling is the most established spoiling method for gradient echo imaging. It is based on a quadratic variation of RF (and receiver) phase angles in successive TRs, coupled with a constant gradient moment at the end of each TR period to create a range of resonance offset angles within each imaging voxel (1). However, it was recognized that RF spoiling yields no...
متن کاملMicrosoft Word - ISMRM2009-000726.DOC
Introduction Due to its high imaging speed and SNR efficiency, spoiled gradient echo imaging plays an important role in many quantitative MR methods. For example, a variable flip angle (VFA) method [1] is now widely used for in vivo T1 mapping due to its time efficiency and large 3D anatomical coverage. Recently, an actual flipangle imaging (AFI) technique [2], which utilizes two interleaved sp...
متن کاملRapid gradient-echo imaging.
Gradient-echo sequences are widely used in magnetic resonance imaging (MRI) for numerous applications ranging from angiography to perfusion to functional MRI. Compared with spin-echo techniques, the very short repetition times of gradient-echo methods enable very rapid 2D and 3D imaging, but also lead to complicated "steady states." Signal and contrast behavior can be described graphically and ...
متن کاملSimultaneous spin-echo refocusing.
A new approach to spin-echo imaging is presented in which the 180 degrees RF pulse refocuses two or more spin-echoes at different positions in the readout period. When simultaneous echo refocusing (SER) is implemented using multiple 180 degrees pulses, an undesirable mixing of stimulated echoes and primary echoes from different slices can occur. A novel periodic gradient spoiler scheme eliminat...
متن کاملOn the steady-state properties of actual flip angle imaging (AFI).
AFI (actual flip angle imaging) represents an interesting approach to map the B(1) transmit fields by measuring the spatial variations of the effective flip angle. However, the accuracy of the technique relies on the adequate spoiling of transverse magnetization. In the present work configuration theory was employed to develop a proper RF and gradient spoiling scheme for the AFI technique, maki...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
عنوان ژورنال:
دوره 77 شماره
صفحات -
تاریخ انتشار 2017