Estimating a just-noticeable difference for ocular comfort in contact lens wearers.

نویسندگان

  • Eric B Papas
  • Lisa Keay
  • Blanka Golebiowski
چکیده

PURPOSE To estimate the just-noticeable difference (JND) in ocular comfort rating by human, contact lens-wearing subjects using 1 to 100 numerical scales. METHODS Ostensibly identical, new contact lenses were worn simultaneously in both eyes by 40 subjects who made individual comfort ratings for each eye using a 100-point numerical ratings scale (NRS). Concurrently, interocular preference was indicated on a five-point Likert scale (1 to 5: strongly prefer right, slightly prefer right, no preference, slightly prefer left, strongly prefer left, respectively). Differences in NRS comfort score (ΔC) between the right and left eyes were determined for each Likert scale preference criteria. The distribution of group ΔC scores was examined relative to alternative definitions of JND as a means of estimating its value. RESULTS For Likert scores indicating the presence of a slight interocular preference, absolute ΔC ranged from 1 to 30 units with a mean of 7.4 ± 1.3 (95% confidence interval) across all lenses and trials. When there was no Likert scale preference expressed between the eyes, absolute ΔC did not exceed 5 units. CONCLUSIONS For ratings of comfort using a 100-point numerical rating scale, the inter-ocular JND is unlikely to be less than 5 units. The estimate for the average value in the population was approximately 7 to 8 units. These numbers indicate the lowest level at which changes in comfort measured with such scales are likely to be clinically significant.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Effect of Three Interventions on Contact Lens Comfort in Symptomatic Wearers: A Randomized Clinical Trial

PURPOSE To investigate whether carrying out various interventions part way through the day influences comfort in symptomatic daily disposable (DD) contact lens wearers. METHODS A subject-masked, randomized, controlled clinical trial was conducted in thirty symptomatic soft lens wearers who wore their habitual DD contact lenses bilaterally for 12 h on two separate days. Five hours after lens a...

متن کامل

Comfort response to rigid and soft hyper-transmissible contact lenses used for continuous wear.

PURPOSE To assess subjective comfort during the first three months of continuous wear of hyper-transmissible soft and rigid contact lenses. METHODS One hundred subjects (50 experienced wearers and 50 neophytes) were fitted with either the Focus Night & Day lens (CIBA Vision, Duluth, GA) or the Z alpha lens (Menicon, Nagoya, Japan). Comfort was monitored at regular intervals using a vertical a...

متن کامل

A multicenter investigation of OPTI-FREE® RepleniSH® multi-purpose disinfecting solution impact on soft contact lens patient comfort

OBJECTIVE Demonstrate that successful soft contact lens wearers using competitive multipurpose solutions report improvement in comfort with OPTI-FREE((R)) RepleniSH((R)) Multi-Purpose Disinfecting Solution (MPDS). METHODS This 30-day, multicentered, open-label study enrolled 109 eligible soft contact lens wearers using COMPLETE((R)) Multi-Purpose Solution (MPS) Easy Rub((R)) or ReNu MultiPlus...

متن کامل

Studies in Contact Lens Care

Hydrogen peroxide-based contact lens disinfection systems are known for their exceptional disinfecting effi cacy and ocular biocompatibility. These traits have enabled hydrogen peroxide disinfection to remain an important option for contact lens wearers over almost three decades. In that time, peroxide disinfection grew to become the market leader and then, with the advent of “no-rub” multi-pur...

متن کامل

Evaluation of Sodium Hyaluronate Lubricating Drops Used before Insertion of Contact Lenses on Symptomatology, Severity, and Intensity of Ocular Dryness

Purpose. This study aimed to evaluate outcomes from the use of a sodium hyaluronate (SH)-based comfort drop, instilled before the insertion of contact lenses, in a population of symptomatic contact lens wearers. Methods. This was a cross-over, open-label, multi-sites study. Subjects were fitted with silicone hydrogel lenses and followed for two months. Before insertion of the lenses, SH drops w...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Investigative ophthalmology & visual science

دوره 52 7  شماره 

صفحات  -

تاریخ انتشار 2011