Long-term effects of polymer-based, slow-release, sirolimus-eluting stents in a porcine coronary model.
نویسندگان
چکیده
BACKGROUND Stent-based delivery of sirolimus (SRL) has shown reduction in neointimal hyperplasia and restenosis. The purpose of this study was to evaluate the chronic vascular response and the expression of cell cycle regulators after SRL-eluting stent implantation in a porcine coronary model. METHODS Forty-nine pigs underwent placement of 109 oversized stents (control, n=54, SRL (140 microg/cm(2)), n=55) in the coronary arteries with histologic analysis and Western blot (PCNA, p27(kip1), CD45, MCP-1, IL-2, IL-6, TNF-beta) at 3, 30, 90 or 180 days. RESULTS At 3 days, the mean thrombus area was similar for control (0.38+/-0.19 mm(2)) and SRL (0.29+/-0.09 mm(2)) stents. After 30 days, the mean neointimal area was significantly less for the SRL (1.40+/-0.35 mm(2)) versus the control stents (2.94+/-1.28 mm(2), p<0.001). At 90 and 180 days, the mean neointimal area was similar for the SRL (3.03+/-0.92 and 3.34+/-0.99 mm(2)) as compared with control stents (3.45+/-1.09 and 3.65+/-1.23 mm(2)). Western blot analysis demonstrated an increased expression of p27(kip1) in the vessel wall at 90 days for the SRL versus control stents (p=0.05) but with increased levels of PCNA in the SRL as compared with control stents (p=0.003). CONCLUSION SRL-eluting stents favorably modulate neointimal formation for 30 days in the porcine coronary model. Long-term inhibition of neointimal hyperplasia is not sustained presumably due to delayed cellular proliferation despite increased levels of the cyclin-dependent kinase p27(kip1) in the vessel wall.
منابع مشابه
Zotarolimus - eluting versus sirolimus - eluting coronary stent implantation review
The safety and efficacy of coronary stents, utilized for treatment of ischemic heart disease, have been evaluated extensively. In comparison with bare-metal stents, first-generation drug-eluting stents more than halved the need for target lesion revascularization, but long-term safety has been questioned, as the first-generation drug-eluting stents seem to be associated with a small, but increa...
متن کاملDrug release kinetics from a drug-eluting stent with asymmetrical coat.
The aim of this study was to investigate the drug release profiles of biodegradable polymer sirolimus- or paclitaxel-eluting stents with asymmetrical coating (BPSES-A or BPPES-A) both in vitro and in vivo. In vitro, the drug release profile was characterized by measuring the drug concentration by HPLC over a time-course. In vivo, a porcine aorta stenting model was employed. The results showed t...
متن کاملIn vitro and in vivo characterization of novel biodegradable polymers for application as drug-eluting stent coatings.
We have used a series of in vitro and in vivo tests to assess the suitability of two new degradable polymers for application as coatings for drug-eluting stents. The first is a family of urethane-linked multi-block copolymers (MBCP) that comprise blocks of lactide, glycolide, epsilon-caprolactone and/or poly(ethylene glycol) chain-extended with 1,4-butanediisocyanate (SynBiosys polymers). The s...
متن کاملSuccinobucol-Eluting Stents Increase Neointimal Thickening and Peri-Strut Inflammation in a Porcine Coronary Model
OBJECTIVE The aim of this study was to assess the efficacy of stent-based delivery of succinobucol alone and in combination with rapamycin in a porcine coronary model. BACKGROUND Current drugs and polymers used to coat coronary stents remain suboptimal in terms of long term efficacy and safety. Succinobucol is a novel derivative of probucol with improved antioxidant and anti-inflammatory prop...
متن کاملRandomized comparison of biodegradable polymer sirolimus-eluting stents versus durable polymer everolimus-eluting stents for percutaneous coronary revascularization: rationale and design of the BIOSCIENCE trial.
BACKGROUND Biodegradable polymers for release of antiproliferative drugs from metallic drug-eluting stents aim to improve long-term vascular healing and efficacy. We designed a large scale clinical trial to compare a novel thin strut, cobalt-chromium drug-eluting stent with silicon carbide-coating releasing sirolimus from a biodegradable polymer (O-SES, Orsiro; Biotronik, Bülach, Switzerland) w...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Cardiovascular research
دوره 63 4 شماره
صفحات -
تاریخ انتشار 2004