A fast model for prediction of respiratory lung motion for image-guided radiotherapy: A feasibility study

نویسندگان

  • M. Zehtabian
  • R. Faghihi
  • M. A. Mosleh-Shirazi
  • A. R. Shakibafard
  • M. Baradaran-Ghahfarokhi
  • Mohammad Amin Mosleh-Shirazi
چکیده

1Medical Radiation Department and Medical Imaging Research Center, School of Engineering, Shiraz University, Shiraz, Iran 2Center for Research in Medical Physics and Biomedical Engineering and Physics Unit, Radiotherapy Department, Namazi Hospital, Shiraz University of Medical Sciences, Shiraz, Iran 3Radiology Department, Shiraz University of Medical Sciences, Shiraz, Iran 4Medical Physics Department, Royal Adelaide Hospital, Adelaide, Australia 5Medical Physics and Medical Engineering Department, School of Medicine, Isfahan University of Medical Sciences, Isfahan, Iran

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

A fast model for prediction of respiratory lung motion for image-guided radiotherapy: A feasibility study

Background: The aim of this work was to study the feasibility of constructing a fast thorax model suitable for simulating lung motion due to respiration using only one CT dataset. Materials and Methods: For each of six patients with different thorax sizes, two sets of CT images were obtained in single-breath-hold inhale and exhale stages in the supine position. The CT images were then ...

متن کامل

Design and Fabrication of a Four-Dimensional Respiratory Phantom for Studying Tumor Movement in Radiotherapy with Magnetic Resonance Imaging

Introduction: In radiation therapy, determining the location of the tumor accurately during irradiation is one of the most important requirements. However, lung tumors are not fixed in a single location and move during irradiation due to respiratory motion. Due to limitations in assessing such movements, using a lung phantom can be useful and operational for their fast, easy an...

متن کامل

Dynamic MLC Tracking Using 4D Lung Tumor Motion Modelling and EPID Feedback

Background: Respiratory motion causes thoracic movement and reduces targeting accuracy in radiotherapy. Objective: This study proposes an approach to generate a model to track lung tumor motion by controlling dynamic multi-leaf collimators. Material and Methods: All slices which contained tumor were contoured in the 4D-CT images for...

متن کامل

Impact of PET - CT motion correction in minimising the gross tumour volume in non-small cell lung cancer

AbstractObjective: To investigate the impact of respiratory motion on localization, and quantification lung lesions for the Gross Tumour Volume utilizing an in-house developed Auto3Dreg programme and dynamic NURBS-based cardiac-torso digitised phantom (NCAT). Methods: Respiratory motion may result in more than 30% underestimation of the SUV values of lung, liver and kidney tumour lesions. The m...

متن کامل

Adaptive prediction of respiratory motion for motion compensation radiotherapy.

One potential application of image-guided radiotherapy is to track the target motion in real time, then deliver adaptive treatment to a dynamic target by dMLC tracking or respiratory gating. However, the existence of a finite time delay (or a system latency) between the image acquisition and the response of the treatment system to a change in tumour position implies that some kind of predictive...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره   شماره 

صفحات  -

تاریخ انتشار 2013