Improved apparatus and procedures for the measurement of solubility of rapidly equilibrating solid–liquid systems to 90°C

نویسندگان

  • S. G. Capewell
  • G. T. Hefter
  • P. M. May
چکیده

An improved apparatus for measuring solubilities of solid–liquid systems at temperatures to 90 °C is described. The apparatus has a high capacity ~up to 56 samples! and a long term temperature stability of 63 mK. The design allows the saturated solution to be multiply sampled and microfiltered at the equilibration temperature, making it particularly suited to rapidly equilibrating systems. The reliability of the apparatus and sampling procedures were tested by measuring the solubilities of NaCl, Na2SO4, and Na2CO3 in water. The data obtained showed a routine precision of 60.05% relative and agreed to within 60.1% of recommended International Union of Pure and Applied Chemistry values. © 1999 American Institute of Physics. @S0034-6748~99!03602-3#

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Predicting Solubility of Isotactic Poly (1-Butene) in Different Organic Solvents by Modified UNIQUAC

The UNIQUAC activity coefficient model is extended to predict solid-liquid equilibrium of isotactic crystalline poly (1-butene), iPBu-1, in different organic solvents. The UNIQUAC activity coefficient model used in this work is based on the concept of group contribution and consists of combinatorial, residual and free volume terms. To account for branching of atom groups in the monomer structur...

متن کامل

A Model For The Residence Time Distribution and Holdup Measurement in a Two Impinging Streams Cyclone Reactor/Contactor in Solid-Liquid Systems

In this paper a two impinging streams cyclone contacting system suitable for handling of solid-liquid systems has been studied. Certain pertinent parameters such as: solid holdup, mean residence time and Residence Time Distribution (RTD) of solid particles have been investigated. A stochastic model based on Markov chains processes has been applied which describe the behavior of solid partic...

متن کامل

Review of preconcentration and solid phase extraction for the determination of trace Lead

Spectrometric techniques for the analysis of trace lead have developed rapidly due to the increasing need for accurate measurements at extremely low levels of this element in diverse matrices. This review covers separation and preconcentration procedures, and considers the features of the application with several spectrometric techniques. The use of an appropriate sample handling technique is a...

متن کامل

Review of preconcentration and solid phase extraction for the determination of trace Lead

Spectrometric techniques for the analysis of trace lead have developed rapidly due to the increasing need for accurate measurements at extremely low levels of this element in diverse matrices. This review covers separation and preconcentration procedures, and considers the features of the application with several spectrometric techniques. The use of an appropriate sample handling technique is a...

متن کامل

Investigation of Solid Dispersion Technique in Improvement of Physicochemical Characteristics of Ibuprofen Powder

     Ibuprofen solid dispersions were prepared by the solvent and fusion-solvent methods using polyethylene glycol (PEG), polyvinylpyrrolidone (PVP), eudragit RS PO, eudragit RL PO and hydroxypropylmethylcellulose (HPMC) as carriers to improve physicochemical characteristics of ibuprofen. The prepared solid dispersions were evaluated for the flowability, solubility characteristics and dissoluti...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره   شماره 

صفحات  -

تاریخ انتشار 1999