Stiffness of compression devices

نویسندگان

  • Masafumi Hirai
  • André Cornu-Thenard
  • Jean-Patrick Benigni
  • Jean-François Uhl
  • Giovanni Mosti
چکیده

The static stiffness index (SSI) is mathematical equation that results in a simple number when the sub-bandage pressure in the supine position is subtracted from the subbandage pressure in the standing weight-bearing position. When SSI data are reported, often a wide range of values is observed for similar materials. The aim of this study was to explore the strength and weakness of the SSI and its measurement. Pressure was recorded with bandaging materials with different resting pressures and properties. Measurements in the upright position were performed under weight and non-weight bearing conditions for up to 12 min of motionless stance. The measurements reveal that the SSI reveals more about the muscle forces of the person included in the system, rather than providing accurate information on the applied system or how well this system is applied. In addition, venous filling has a major effect on the final SSI. When performed under similar conditions, the SSI is able to differentiate between elastic and inelastic materials. The SSI gives us a rough estimate of the effectiveness of an applied system but interpretation is influenced by the muscle forces of the person being bandaged as well as the measured effects of venous filling and, because of that, the timing of the measurements. Future guidelines on measuring the SSI should include that the final standing pressure value should be taken when a stable recording over a certain period is observed.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

In vitro measurements of compression bandages and bandage systems: a review of existing methods and recommendations for improvement

In this article an overview is presented of identified devices that are or can be used for in vitro pressure and stiffness measurements of compression bandages and bandage systems. The performance of these devices has been evaluated on several parameters as well as the clinical relevance of the findings. In addition, recommendations for improvement and standardization of future measurements fro...

متن کامل

Optical pulse compression based on nonlinear silicon waveguides and chirped Bragg gratings

Due to the growing demand for higher bandwidth, employing optical devices instead of electronic devices in data transmission systems has attracted much attention in recent years. Optical switches, modulators and wavelength converters are a few examples of the required optical devices. CMOS compatible fabrication of these devices, leads to much more growing of this technology. Optical pulse comp...

متن کامل

Semi-active Control of Building Structures using Variable Stiffness Device and Fuzzy Logic

Semi-active control devices, also called “Intelligent” control devices, constitute the positive aspects of both the passive and active control devices. A semi-active control strategy is similar to the active control strategy, but this control device has been shown to be more energy-efficient than active devices. A particular type of semi-active control device, the Variable Stiffness Device (VSD...

متن کامل

Stiffness of the locking compression plate as an external fixator for treating distal tibial fractures: a biomechanics study

BACKGROUND Locking compress plate, as external fixator, is an attractive technique for distal tibial fracture treatment. But it still remains unclear whether the external LCP has sufficient stiffness. Thus, the present study aims to make a comprehensive evaluation of the stiffness of external locking compress plate when it is used as an external fixator in distal tibial fractures treatment. M...

متن کامل

Classification of compression bandages: practical aspects.

BACKGROUND Compression bandages appear to be simple medical devices. However, there is a lack of agreement over their classification and confusion over the use of important terms such as elastic, inelastic, and stiffness. OBJECTIVES The objectives were to propose terms to describe both simple and complex compression bandage systems and to offer classification based on in vivo measurements of ...

متن کامل

Bar diameter is an important component of knee-spanning external fixator stiffness and cost.

The authors' objective was to determine the effects of bar diameter on the stiffness and cost of a knee-spanning external fixator. The authors studied 2 versions of an external fixator with a difference in bar diameter (small bars, 8-mm diameter; large bars, 11-mm diameter). Fixators were tested using frame dimensions and a synthetic fracture model appropriate for a tibial plateau fracture. Fiv...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره   شماره 

صفحات  -

تاریخ انتشار 2013