Unreliable Tracking Ability of the Third-Generation FloTrac/Vigileo™ System for Changes in Stroke Volume after Fluid Administration in Patients with High Systemic Vascular Resistance during Laparoscopic Surgery
نویسندگان
چکیده
BACKGROUND The FloTrac/Vigileo™ system does not thoroughly reflect variable arterial tones, due to a lack of external calibration. The ability of this system to measure stroke volume and track its changes after fluid administration has not been fully evaluated in patients with the high systemic vascular resistance that can develop during laparoscopic surgery. METHODS In 42 patients undergoing laparoscopic prostatectomy, the stroke volume derived by the third-generation FloTrac/Vigileo™ system (SV-Vigileo), the stroke volume measured using transesophageal echocardiography (SV-TEE) as a reference method, and total systemic vascular resistance were evaluated before and after 500 ml fluid administration during pneumoperitoneum combined with the Trendelenburg position. RESULTS Total systemic vascular resistance was 2159.4 ± 523.5 dyn·s/cm5 before fluid administration. The SV-Vigileo was significantly higher than the SV-TEE both before (68.8 ± 15.9 vs. 57.0 ± 11.0 ml, P < 0.001) and after (73.0 ± 14.8 vs. 64.9 ± 12.2 ml, P = 0.003) fluid administration. During pneumoperitoneum combined with the Trendelenburg position, Bland-Altman analysis for repeated measures showed a 53.8% of percentage error between the SV-Vigileo and the SV-TEE. Four-quadrant plot (69.2% of a concordance rate) and polar plot analysis (20.6° of a mean polar angle, 16.4° of the SD of a polar angle, and ±51.5° of a radial sector containing 95% of the data points) did not indicate a good trending ability of the FloTrac/Vigileo™ system. CONCLUSIONS The third-generation FloTrac/Vigileo™ system may not be useful in patients undergoing laparoscopic surgery, based on unreliable performance in measuring the stroke volume and in tracking changes in the stroke volume after fluid administration during pneumoperitoneum combined with the Trendelenburg position.
منابع مشابه
Third-generation FloTrac/Vigileo does not reliably track changes in cardiac output induced by norepinephrine in critically ill patients.
BACKGROUND The ability of the third-generation FloTrac/Vigileo software to track changes in cardiac index (CI) induced by volume expansion and norepinephrine in critically ill patients is unknown. METHODS In subjects with circulatory failure, we administered volume expansion (20 subjects) and increased (20 subjects) or decreased (20 subjects) the dose of norepinephrine. We measured arterial p...
متن کاملStroke Volume Variation for Prediction of Fluid Responsiveness in Patients Undergoing Gastrointestinal Surgery
BACKGROUND Stroke volume variation (SVV) has been shown to be a reliable predictor of fluid responsiveness. However, the predictive role of SVV measured by FloTrac/Vigileo system in prediction of fluid responsiveness was unproven in patients undergoing ventilation with low tidal volume. METHODS Fifty patients undergoing elective gastrointestinal surgery were randomly divided into two groups: ...
متن کاملDynamic variables of fluid responsiveness during pneumoperitoneum and laparoscopic surgery.
BACKGROUND Few data exist on dynamic variables predicting fluid responsiveness during laparoscopic surgery. The aim of this study was to explore the effects of laparoscopy on four dynamic variables: respiratory variations in pulse pressure (ΔPP), stroke volume variation by Vigileo/FloTrac (SVV (Vigileo) ), pleth variability index (PVI) and respiratory variations in pulse oximetry plethysmograph...
متن کاملChanges in stroke volume induced by passive leg raising in spontaneously breathing patients: comparison between echocardiography and Vigileo™/FloTrac™ device
INTRODUCTION Passive leg raising (PLR) is a simple reversible maneuver that mimics rapid fluid loading and increases cardiac preload. The effects of this endogenous volume expansion on stroke volume enable the testing of fluid responsiveness with accuracy in spontaneously breathing patients. However, this maneuver requires the determination of stroke volume with a fast-response device, because ...
متن کاملThe ability of left ventricular end-diastolic volume variations measured by TEE to monitor fluid responsiveness in high-risk surgical patients during craniotomy: a prospective cohort study
BACKGROUND This study was aimed to evaluate the ability of left ventricular end-diastolic volume variations (LVEDVV) measured by transesophageal echocardiography (TEE) compared with stroke volume variation (SVV) obtained by the FloTrac/Vigileo monitor to predict fluid responsiveness, in patients undergoing craniotomy with goal direct therapy. METHODS We used SVV obtained by the FloTrac/Vigile...