Radiological Control of the Floating Mass Transducer Attached to the Round Window

نویسندگان

  • Ingo Todt
  • G. Rademacher
  • J. Wagner
  • P. Mittmann
  • Dietmar Basta
  • Arne Ernst
چکیده

The surgical rehabilitation of mixed hearing losses can be performed by coupling the floating mass transducer of the Vibrant Soundbridge to the round window. The quality of coupling the floating mass transducer to the round window is crucial for the audiological outcome. It was the aim of this study to further observe the different patterns of floating mass transducer position at the round window. We compared twenty patients with mixed hearing loss implanted with a floating mass transducer attached to the round window and 24 surgeries between 5/2007 and 6/2010. An evaluation of the chronological observation of the flat panel angiography-controlled position of the floating mass transducer at the round window with relation to the surgical report and the audiological outcome was done. We observed no changes in the mean pre- and postbone conduction thresholds. The floating mass transducer position was variable and could be radiologically classified and correlated with the audiologically outcome. A learning curve was observed from the earlier to later implantations. Postoperative, radiological evaluation of the location and angle of the floating mass transducer by means of flat panel tomography allowed us to classify the floating mass transducer position at the round window into 4 groups.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Vibroplasty in mixed and conductive hearing loss: comparison of different coupling methods.

OBJECTIVES/HYPOTHESIS To evaluate modified coupling techniques of the Vibrant Soundbridge system in patients with mixed and conductive hearing loss and to compare it with conventional vibroplasty. STUDY DESIGN Retrospective study. METHODS Two different groups were evaluated: 1) nine cases of conventional incus vibroplasty in comparison with 2) nine patients with modified coupling of the flo...

متن کامل

Importance of Floating Chondrons in Cartilage Tissue Engineering

BACKGROUND Dedifferentiation of chondrocytes remains a major problem for cartilage tissue engineering. Chondrocytes loss differentiated phenotype in in vitro culture that is undesired for repair strategies. The chondrocyte is surrounded by a pericellular matrix (PCM), together forming the chondron. PCM has a positive effect on the maintenance of chondrocyte phenotype during culture in compar...

متن کامل

An optical coherence tomography study for imaging the round window niche and the promontorium tympani

Tympanosclerosis may involve the tympanic membrane, the ossicles, as well as the oval and round window niche, respectively. The surgical treatment of the obliterated oval window niche is most challenging. Beside stapesplasty, vibroplasty with coupling the floating mass transducer (FMT) onto the round window niche and into a new, so-called third window is indicated. In the latter situation, dril...

متن کامل

Experience with the Vibrant Soundbridge RW-Coupler for round window Vibroplasty with tympanosclerosis

Abstract Usage of the Vibrant Soundbridge (VSB) with round window (RW)-Coupler placement at the RW has been shown to successfully treat mixed hearing loss. Coupling between the VSB's floating mass transducer (FMT) and the RW membrane is difficult in the case of sclerosis in the RW and drilling down the bony lip until the RW membrane can be seen completely can possibly induce a perilymphatic f...

متن کامل

Evaluation of round window stimulation using the floating mass transducer by intracochlear sound pressure measurements in human temporal bones.

HYPOTHESIS Round window (RW) stimulation with a floating mass transducer (FMT) can be studied experimentally and optimized to enhance auditory transduction. BACKGROUND The FMT (MED-EL Vibrant Soundbridge) has been recently implanted in patients with refractory conductive or mixed hearing loss to stimulate the RW with varying degrees of success. The mechanics of RW stimulation with the FMT hav...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره 2013  شماره 

صفحات  -

تاریخ انتشار 2013