Using Cone Beam Computed Tomography Angle for Predicting the Outcome of Horizontal Bone Augmentation.

نویسندگان

  • Carlos Garaicoa
  • Fernando Suarez
  • Jia-Hui Fu
  • Hsun-Liang Chan
  • Alberto Monje
  • Pablo Galindo-Moreno
  • Hom-Lay Wang
چکیده

BACKGROUND The aim of this study was to assess the influence of ridge morphology on the amount of horizontal bone augmentation achieved with the sandwich bone augmentation (SBA) technique in the reconstruction of buccal dehiscence defects on dental implants. METHODS Cone beam computed tomography (CBCT) was used to assess bone width changes in 26 patients who participated in a randomized controlled trial conducted in 2008 to 2011. The amount of horizontal bone gain was evaluated at four different levels (3, 6, 9, and 12 mm apical to the alveolar crest) and three different time points (T1: baseline, T2: at time of graft placement, and T3: 6 months later). Different morphological characteristics of the alveolar ridge were also evaluated to determine their influence on horizontal bone augmentation. A total of 78 CBCT scans were assessed. RESULTS Comparison of the changes in ridge morphology at all measurement locations showed an overall ridge width gain of 2.30 ± 2.20 mm after 6 months. The use of membranes and the angulation of the concavity played a role in influencing the outcomes of the SBA technique. Critical crest angulation (CA) is 150° for bone gain at 9 mm apical to the crest. When CA is smaller than 150°, the horizontal bone gain was 4.3 ± 2.2 mm; if CA is greater than 150°, the gain was significantly lower at 1.3 ± 1.7 mm (p = .001). CONCLUSIONS SBA is a reliable and predictable technique to gain horizontal ridge width with simultaneous implant placement. Crest ridge angulation can be used as a tool to predict bone gain at 9 mm apical to the bone crest.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Comparing the Accuracy of Cone Beam Computed Tomography,Digital Intraoral Radiography and Conventional Intraoral Radiography in the Measurement of Periodontal Bone Defects

Background and Aim: Cone beam computed tomography (CBCT) produces high-quality data in periodontal diagnosis and treatment planning. The aim of this study was to compare the accuracy of CBCT with intraoral digital and conventional radiography in the measurement of periodontal bone defects.  Methods and Materials: In this diagnostic research, two hundred and eighteen artificial osseous d...

متن کامل

Cone-beam computed tomography performance and endodontic filling material influence in the diagnosis of horizontal root fracture

Introduction: The aim of this study was to investigate the accuracy of Cone-beam computed tomography(CBCT) in detecting the horizontal root fractures (HRFs) in teeth with and without gutta-percha. Materials & Methods: This in vitro study was performed on 100 mandibular and maxillary single-rooted teeth. In 55 samples, the canals were prepared. Then, the horizontal fracture was induced randomly...

متن کامل

Measuring the thickness of buccal cortical bone of maxillary premolar teeth by cone beam computed tomography technique

Background and Aims: Immediate implant placement following tooth extraction is a treatment with many advantages. Alveolar bone preservation after immediate implant, need minimum of 2 mm thickness in buccal bone plate. The aim of this study was to evaluate the thickness of buccal cortical bone of maxillary premolars by Cone Beam Computational Tomography (CBCT) technique. Materials and Methods: ...

متن کامل

A comparative evaluation of cone-beam computed tomography and multi-slice computed tomography in the diagnosis of sheep mandibular bone defect: an in vitro study

Introduction: Diagnosis of lesions and bone defects is very important and there is a lack of substantial studies on the most appropriate method for bone defect measurement. Hence, the aim of this study is to evaluate the accuracy of multi-slice computed tomography (MSCT) and cone-beam computed tomography (CBCT) in the diagnosis of mandibular bone defects present in sheep. Material & Methods: T...

متن کامل

Correlation Between Tissue Densities in Computed Tomography and Three Different Cone-Beam Computed Tomography Units (In Vitro)

Background and Aim: Bone density is of great assistance in the selection of the proper implant site. The present study aimed to assess the correlation between tissue densities in computed tomography (CT) and three different cone-beam computed tomography (CBCT) units. Materials and Methods: In this descriptive study, a radiographic phantom consisting of a transparent polymethyl methacrylate (PM...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Clinical implant dentistry and related research

دوره 17 4  شماره 

صفحات  -

تاریخ انتشار 2015