Influence of biological and analytical variation on urine measurements for monitoring exposure to cadmium.

نویسندگان

  • H J Mason
  • N R Williams
  • M G Morgan
  • A J Stevenson
  • S Armitage
چکیده

OBJECTIVE To define the mean intraindividual biological variation in urinary concentrations of cadmium and retinol binding protein (RBP) in untimed, random urine samples and the influence of creatinine or specific gravity correction on reducing this variation. The relation between biological variation and analytical variation in defining uncertainty in a single measurement and significant differences between successive measurements was explored. METHODS Repeat measurement study in subjects with either high historical exposure to cadmium but without current exposure, or unexposed volunteers. Standard statistical tools used in clinical laboratory medicine were applied to define intraindividual biological and analytical variation. RESULTS AND CONCLUSION Both creatinine and specific gravity correction of urinary cadmium measurements in random urine samples seem to reduce the intraindividual variability compared with uncorrected values. With a standard definition, acceptable long term analytical precision for measurements of cadmium and RBP combined with creatinine analyses should be < 9% and < 15% respectively. The mean intraindividual biological variation of cadmium and RBP, expressed as creatinine corrected, was 18% and 40% respectively in the subjects exposed to cadmium. With the analytical precision used, significant differences (p < 0.05) between consecutive measurements for creatinine corrected urinary cadmium and RBP would need to show changes of > 54% and > 110% respectively. The relation between significant differences in consecutive results and differences in the analytical precision of the method used to measure the samples is described.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Biological Monitoring of Healthcare Workers Exposed to Antineoplastic Drugs: Urinary Assessment of Cyclophosphamide and Ifosfamide

Exposure of health care workers to antineoplastic drugs and subsequent adverse health effects is still an open issue. Very little has been studied on the extent of occupational exposure and handling conditions of antineoplastic drugs in Iran. We aimed to determine cyclophosphamide and ifosfamide concentrations in the urine samples of oncology healthcare workers. In addition, we assessed workpla...

متن کامل

Biological Monitoring of Healthcare Workers Exposed to Antineoplastic Drugs: Urinary Assessment of Cyclophosphamide and Ifosfamide

Exposure of health care workers to antineoplastic drugs and subsequent adverse health effects is still an open issue. Very little has been studied on the extent of occupational exposure and handling conditions of antineoplastic drugs in Iran. We aimed to determine cyclophosphamide and ifosfamide concentrations in the urine samples of oncology healthcare workers. In addition, we assessed workpla...

متن کامل

BIOLOGICAL MONITORING OF MERCURY EXPOSURE IN DENTISTS OF TEHRAN

In order to assess the risk for mercury poisoning in dentists, urine specimens were collected and analysed from 250 dentists (190 male, 60 female). Subject data and pertinent health symptoms were asked via a questionnaire. The results indicate that the mean and standard deviation of mercury values were 51.3± 38.0 µg/L, while 27.2 percent of dentists had levels within normal limits (0-19 µg/...

متن کامل

کاربرد روش استخراج فاز جامد و جاذب XAD-4 جهت تعیین مقدار کادمیوم در نمونه های مو و ناخن کارگران یک صنعت فلزی

Background and aims: Cadmium is a common industrial and environmental contaminant causing adverse health effects on respiratory system and kidney. This has been classified as a human carcinogen. Biological monitoring of cadmium and its measurement in urine, hair, and nail samples can be considered as an evaluation of the internal dose. Because of trace concentration of analytes in biological sa...

متن کامل

Disposable single-use electrochemical sensor: A novel hollow fiber based tool for environmental monitoring of cadmium

The objective of this study is to design a simple, fast, sensitive and single-use electrode with the simultaneous capability of preconcentration and measuring, for application in a three-electrode voltammetry system to identify and measure the heavy metal cadmium. The design process of this sensor consists of several stages. The polyurethane foam and multi walled carbon nanotubes nanoparticles ...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Occupational and environmental medicine

دوره 55 2  شماره 

صفحات  -