Peak detection in mass spectrometry data using repeated measurements – A graphical approach
نویسندگان
چکیده
1Department of Statistics, University of Southern Denmark, Campusvej 55, 5230 Odense M, Denmark 2Department of Gynecology and Obstetrics, Odense University Hospital, Sdr. Boulevard 29, 5000 Odense C, Denmark 3Department of Biochemistry & Molecular Biology, Proteom Research Group, University of Southern Denmark, Campusvej 55, 5230 Odense M, Denmark 4 Department of Biochemistry, Pharmacology & Genetics, Odense University Hospital, Sdr. Boulevard 29, 5000 Odense C, Denmark 5 Department of Oncology, Odense University Hospital, Sdr. Boulevard 29, 5000 Odense C, Denmark
منابع مشابه
A New Method of Peak Detection for Analysis of Comprehensive Two-dimensional Gas Chromatography Mass Spectrometry Data.
We develop a novel peak detection algorithm for the analysis of comprehensive two-dimensional gas chromatography time-of-flight mass spectrometry (GC×GC-TOF MS) data using normal-exponential-Bernoulli (NEB) and mixture probability models. The algorithm first performs baseline correction and denoising simultaneously using the NEB model, which also defines peak regions. Peaks are then picked usin...
متن کاملBiomarker discovery for arsenic exposure using functional data. Analysis and feature learning of mass spectrometry proteomic data.
Plasma biomarkers of exposure to environmental contaminants play an important role in early detection of disease. The emerging field of proteomics presents an attractive opportunity for candidate biomarker discovery, as it simultaneously measures and analyzes a large number of proteins. This article presents a case study for measuring arsenic concentrations in a population residing in an As-end...
متن کاملImproving peak detection in high-resolution LC/MS metabolomics data using preexisting knowledge and machine learning approach
MOTIVATION Peak detection is a key step in the preprocessing of untargeted metabolomics data generated from high-resolution liquid chromatography-mass spectrometry (LC/MS). The common practice is to use filters with predetermined parameters to select peaks in the LC/MS profile. This rigid approach can cause suboptimal performance when the choice of peak model and parameters do not suit the data...
متن کاملAccurate LC Peak Boundary Detection for 16O/18O Labeled LC-MS Data
In liquid chromatography-mass spectrometry (LC-MS), parts of LC peaks are often corrupted by their co-eluting peptides, which results in increased quantification variance. In this paper, we propose to apply accurate LC peak boundary detection to remove the corrupted part of LC peaks. Accurate LC peak boundary detection is achieved by checking the consistency of intensity patterns within peptide...
متن کاملPrepMS: TOF MS data graphical preprocessing tool
UNLABELLED We introduce a simple-to-use graphical tool that enables researchers to easily prepare time-of-flight mass spectrometry data for analysis. For ease of use, the graphical executable provides default parameter settings, experimentally determined to work well in most situations. These values, if desired, can be changed by the user. PrepMS is a stand-alone application made freely availab...
متن کامل