Application of a newly developed, highly sensitive camera and a 3-dimensional high-definition television system in experimental ophthalmic surgeries.
نویسندگان
چکیده
OBJECTIVE To apply a new television system, which displays highly sensitive, high-quality 3-dimensional (3-D) images, in performing experimental ophthalmic surgeries. METHODS By combining a high-gain avalanche rushing-amorphous photoconductor (HARP) camera, recently developed in Japan, which has 600 times greater sensitivity than conventional television cameras, and a single-camera, 3-D high-definition television system, which displays high-quality 3-D images, we performed cataract/intraocular lens surgeries and pars plana vitrectomies under various illumination intensities in pig cadaver eyes. RESULTS Cataract/intraocular lens surgeries were performed using 7.3% the intensity of ordinary surgical microscopic illumination; vitrectomies were performed using 30.2% the intensity of an ordinary endoillumination probe with the HARP camera and by observing the stereoscopic display of the single-camera 3-D high-definition television system. Images identical to those observed by the surgeon were displayed on the stereoscopic display monitor. CONCLUSION The system not only allowed surgeries to be performed under lower intensities of operating light but also provided real-time, highly sensitive 3-D images identical to those observed by the surgeon; thus, the device may be effectively used for education, team surgery, and telesurgery. CLINICAL RELEVANCE The new television system for ocular surgeries to be performed under lower intensities of operating light as well as providing real-time, highly sensitive 3-D images identical to those observed by the surgeon may be effectively used for education and telesurgery.
منابع مشابه
Developed Method Application for Nitrite Ion (NO2¯ ) Analysis of Tib -186 Macrophage Like Cell Lines by Rapid Isocratic HPLC System with High Sensitive Glassy Carbon Electrochemical Detector
A rapid isocratic method of high performance liquid chromatography system (HPLC) with a glassy carbon working electrode of electrochemical detector is set up for quantitative detection of trace amount of nitrite ion (NO2¯) in aqueous protein containing cell lysate, cell media, plasma, serum, urine and other body fluids. The solid extraction reversed phase cartridges ...
متن کاملEvaluation of the performance of parallel-hole collimator for high resolution small animal SPECT: A Monte Carlo study
Introduction: Image quality and accuracy of in vivo activity quantification in SPECT are affected by collimator penetration and scatter components, especially in high energy imaging. These phenomena highly depend on the collimator characteristic and photon energy. The presence of penetrated and scattered photons from collimator in SPECT images degrades spatial resolution, contr...
متن کاملA Highly Sensitive Kinetic Spectrophotometric Method for the Determination of Ascorbic Acid in Pharmaceutical Samples
In this study, a new reaction system for quantitative determination of ascorbic acid was introduced. The developed method is based on inhibitory effect of ascorbic acid on the Orange G-bromate system. The change in absorbance was followed spectrophotometrically at 478 nm. The dependence of sensitivity on the reaction variables including reagents concentration, temperature and time was investiga...
متن کاملDosimetry Comparison of Water Phantom and Complete Eye Definition for 125I and 103Pd Brachytherapy Plaques
Introduction: In this paper, by complete definition of human eye containing the various parts and their materials, the difference between this model and a homogeneous water phantom are compared for two ophthalmic plaques using 125I and 103Pd. Material and methods: The simulation of the two phantoms were performed in the MCNP-4C code and by using the geometry of a three-dimensional eye, differen...
متن کاملDesign and Implementation of an Intelligent Photogrammetric System for Control and Guidance of Reconstructive Surgery
The digital image contains efficient and useful information which enables measurement and data acquisition. One of the methods that facilitate measuring and interpreting objects, using the image solely, is close-range photogrammetry. Among the various fields of science, whenever a precise measurement is required, this approach can be applied. One of these fields is Medical Sciences that due to ...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Archives of ophthalmology
دوره 117 12 شماره
صفحات -
تاریخ انتشار 1999