Field sample preconcentration of copper in sea water using chelating minicolumns subsequently incorporated on a flow-injection-flame atomic absorption spectrometry system.
نویسندگان
چکیده
A field flow preconcentration system for copper determination in seawater is described. Seawater samples are collected and preconcentrated in situ by passing them using a peristaltic pump through a minicolumn packed with Amberlite XAD-4 impregnated with the complexing agent 1-(2-pyridylazo)-2-naphthol. Thus, copper is preconcentrated without the interference of the saline matrix. Once in the laboratory, the minicolumns loaded with copper are incorporated on a flow injection system and eluted with a small volume of a 20% (v/v) ethanolic solution of 0.5 mol L-1 hydrochloric acid into the nebuliser-burner system of a flame atomic absorption spectrometer. The analytical figures of merit for the determination of copper are as follows: detection limit (3s), 0.06 microgram L-1; precision (RSD), 1.2% for 2 micrograms L-1; enrichment factor, 30 (using 25 mL of sample and 83 microL of eluent). Analysis of certified reference materials (SLEW-3 and NASS-5) showed good agreement with the certified value. This procedure was applied to the determination of copper in seawater samples from Galicia (Spain).
منابع مشابه
Automated On-line Preconcentration System for Electrothermal Atomic Absorption Spectrometry for the Determination of Copper and Molybdenum in Sea-water
absorption spectrometry was developed. The performance of retain transition metal ions. After the sample loading step, the the on-line preconcentration system was tested by determining metal ions are stripped from the column with a suitable eluent Cu and Mo in sea-water. Calibration graphs constructed from and directly injected into the nebulizer of a flame atomic the preconcentration of standa...
متن کاملIon Pair Dispersive Liquid-Liquid Microextraction for the Determination of Trace Amounts of Copper(II) in Soil, Multivitamin Tablet, Tea and Water Samples Using Flame Atomic Absorption Spectrometry
Ion pair dispersive liquid- liquid microextraction (IP-DLLME) method combined with flame atomic absorption spectrometry was proposed for the determination of trace amounts of copper(II). By using pyrocatechol violet as chelating agent and cetyltrimethyl ammonium bromide as an ion pairing agent, the trace amount of copper(II) was extracted in chloroform. The factors influencing the formation cop...
متن کاملCloud Point Extraction of Trace Amounts of Copper and Its Determination by Flow Injection Flame Atomic Absorption Spectrometry
A simple and convenient method based on cloud point extraction was proposed for the determination of copper. The extraction was carried out in the presence of 2-[(2-mercaptophenylimino)methyl]phenol (MPMP) as the chelating ligand and octylphenoxypolyethoxyethanol (Triton X-114) as the non-ionic surfactant. After phase separation, the surfactant rich phase containing the complex was diluted with...
متن کاملApplication of Sulfur Nanoparticles as a Solid Phase Extraction Sorbent for the Preconcentration of Lead(II) and Palladium(II) in Environmental Samples Prior to Flame Atomic Absorption Spectrometry Determination
The application of sulfur nanoparticles as an efficient adsorbent for the solid-phase extraction and determination of the trace amounts of Pb and Pd ions was investigated in environmental samples using flame atomic absorption spectrometry. Effects of various parameters such as pH, flow rate of sample and eluent, type and concentration of eluent, sample volume, amount of adsorbent and interferin...
متن کاملDispersive Liquid-Liquid Microextraction Based on Solidification of Floating Organic Drop Combined with Flame Atomic Absorption Spectrometry for Preconcentration and Determination of Thallium(III) in Water Samples
Dispersive Liquid-Liquid MicroExtraction technique based on Solidification of a Floating Organic drop (DLLME-SFO) combined with flame atomic absorption spectrometry was developed for determination of thallium in water sample. An appropriate mixture of acetone and 1-undecanol was rapidly injected into an aqueous sample containing TlCl4- which forms an ion pair with bril...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- The Analyst
دوره 126 6 شماره
صفحات -
تاریخ انتشار 2001