Spinal cord ischemia after elective endovascular stent-graft repair of the thoracic aorta.

نویسندگان

  • Nobuyoshi Kawaharada
  • Kiyofumi Morishita
  • Yoshihiko Kurimoto
  • Hideki Hyodoh
  • Toshiro Ito
  • Ryo Harada
  • Kenji Kuwaki
  • Tetsuya Higami
چکیده

BACKGROUND We reviewed our experience to investigate the determinants of paraplegia/paraparesis after endovascular stent-graft repair of the thoracic aorta, to assess the influence of the artery of Adamkiewicz (ARM) detected by preoperative magnetic resonance angiography (MRA) and to identify patients at risk. METHODS Over a 5-year period (March 2001-June 2006), 149 patients underwent elective endovascular stent-graft repair of the descending thoracic aorta. Patient demographics and perioperative factors relating to the endovascular procedure were evaluated by using univariate statistical analyses. To assess the influence of the ARM in the thoracolumbar region, patients in whom ARM was detected by preoperative MRA were divided into two groups: patients who had occlusion of the intercostal artery for ARM due to stent-graft (group A, n=33) and patients who had patency of the intercostal artery for ARM following stent-graft (group B, n=38). RESULTS Five (3.6%) of the 144 patients had paraparesis/paraplegia. Two of these five patients had previously undergone operation for total arch replacement with elephant trunk and one had surgery for descending aortic repair. Univariate analyses identified only prior aortic surgery as a significant risk factor (p=0.04). Paraparesis/paraplegia rates were 10% (three patients) in group A and 0% in group B (p=0.09). CONCLUSION Prior thoracic aortic replacement was found to be a significant predictor of spinal cord ischemia, and therefore vigilance is needed regarding occlusion of the intercostal artery for ARM detected prior to stent-graft repair.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Spinal cord ischemia after elective stent-graft repair of the thoracic aorta.

OBJECTIVES Neurologic deficit after endovascular treatment of the thoracic aorta is a complication reported with variable frequency that may be associated with severe morbidity and mortality. The mechanism of spinal cord ischemia appears to be multifactorial and remains ill-defined. We reviewed our experience to investigate the determinants of paraplegia after stent-graft repair of the thoracic...

متن کامل

Two-Stage Endovascular Repair for Concurrent Penetrating Atherosclerotic Ulcers of the Thoracic and Abdominal Aorta

We report a case of concurrent saccular aneurysms caused by a penetrating atherosclerotic ulcer of the thoracic and abdominal aorta that were successfully treated by staged endovascular repair. Even though surgical open repair or endovascular repair is the treatment option, use of endovascular repair is now accepted as an alternative treatment to surgery in selected patients. To prevent contras...

متن کامل

Hybrid procedure in pseudoaneurysm of the descending thoracic aorta in Hospital Kuala Lumpur.

Conventional open repair for Thoracoabdominal aortic aneurysm (TAA) is associated with high morbidity and mortality. Spinal cord ischemia (SCI), renal failure, bowel ischemia and mortality are established complications following this procedure. With the advent of endovascular stent technology, various novel approaches have been described to reduce these complications, namely fenestrated stent g...

متن کامل

Recurrent spinal cord ischemia after endovascular stent grafting for chronic traumatic aneurysm of the aortic isthmus.

This report describes the development of recurrent spinal cord ischemia in a patient after insertion of a stent graft into the upper segment of the descending thoracic aorta for the treatment of a chronic traumatic aneurysm of the aortic isthmus. Intraoperatively, the stent covered the ostium of the left T7 artery, which was shown to give rise to a middle dorsal artery by postoperative spinal c...

متن کامل

Neurophysiological monitoring during thoracoabdominal aortic endovascular stent graft implantation.

OBJECTIVE The aim of this study was to evaluate the benefit of neurophysiological monitoring during thoracic and thoracoabdominal endovascular stent graft implantation. METHODS The spinal cords of 21 patients undergoing endovascular stent graft implantation on the thoracic and thoracoabdominal aorta were monitored with transcranial motor-evoked potentials (tcMEP) and somatosensory-evoked pote...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • European journal of cardio-thoracic surgery : official journal of the European Association for Cardio-thoracic Surgery

دوره 31 6  شماره 

صفحات  -

تاریخ انتشار 2007