Unknown biological mixtures evaluation using STR analytical quantification.

نویسندگان

  • Sadeep Shrestha
  • Steffanie A Strathdee
  • Karl W Broman
  • Michael W Smith
چکیده

Allelic quantification of STRs, where the presence of three or more alleles represents mixtures, provides a novel method to identify mixtures from unknown biological sources. The allelic stutters resulting in slightly different repeat containing products during fragment amplification can be mistaken for true alleles complicating a simple approach to mixture analysis. An algorithm based on the array of estimated stutters from known samples was developed and tuned to maximize the identification of true non-mixtures through the analysis of three pentanucleotide STRs. Laboratory simulated scenarios of needle sharing generated 58 mixture and 38 non-mixture samples that were blinded for determining the number of alleles. Through developing and applying an algorithm that additively estimates stuttering around the two highest peaks, mixtures and non-mixtures were characterized with sensitivity of 77.5, 82.7 and 58% while maintaining the high specificity of 100, 97.4 and 100 for the W, X, and Z STRs individually. When all three STRs were used collectively, the resulting sensitivity and specificity was 91.4 and 97.4%, respectively. The newly validated approach of using multiple STRs as highly informative biomarkers in unknown sample mixture analyses has potential applications in genetics, forensic science, and epidemiological studies.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Standard Addition Connected to Selective Zone Discovering for Quantification in the Unknown Mixtures

Univariate calibration method is a simple, cheap and easy to use procedure in analytical chemistry. A univariate analysis will be successful if a selective signal can be found for the analyte(s). In this work, two simple ways were used to find the selective signals, spectral ratio plot (SRP) and loading plot (LP). Both of them were able to discover the selective regions in the recorded data set...

متن کامل

Spectrophotometric Multicomponent Analysis of Ternary and Quaternary Drug Mixtures in Human Urine Samples by Analyzing First-order Data

      A new method was developed for the spectral resolution by further determination of three- and  four-component  mixtures  of  drugs in urine samples through  the complementary application of multivariate curve resolution-alternating least squares with correlation  constraint. In the current study, a simple method was proposed to construct a calibration set for the mixture of drugs in the p...

متن کامل

NIST mixed stain studies #1 and #2: interlaboratory comparison of DNA quantification practice and short tandem repeat multiplex performance with multiple-source samples.

The Mixed Stain Study 1 (MSS1, Apr.-Nov. 1997) and Mixed Stain Study 2 (MSS2, Jan.-May 1999) evaluated multiplexed short-tandem repeat (STR) DNA typing systems with samples containing DNA from more than one source. These interlaboratory challenge studies evaluated forensic STR measurement, interpretation, and reporting practice using well-characterized samples of very different analytical diffi...

متن کامل

Comparison of Quality Evaluation of Agricultural Distillates Using Prototype of Electronic Nose and Fast/Flash GC

Comparison of Quality Evaluation of Agricultural Distillates Using Prototype of Electronic Nose and Fast/Flash GC Tomasz Dymerski*, Jacek Gębicki, Jacek Namieśnik Department of Analytical Chemistry, Chemical Faculty, Gdansk University of Technology, 11/12 G. Narutowicza Str., 80-233 Gdańsk, Poland. Department of Chemical and Process Engineering, Chemical Faculty, Gdansk University of Technology...

متن کامل

Development of a Univariate Membrane-Based Mid-Infrared Method for Protein Quantitation and Total Lipid Content Analysis of Biological Samples

Biological samples present a range of complexities from homogeneous purified protein to multicomponent mixtures. Accurate qualification of such samples is paramount to downstream applications. We describe the development of an MIR spectroscopy-based analytical method offering simultaneous protein quantitation (0.25-5 mg/mL) and analysis of total lipid or detergent species, as well as the identi...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Electrophoresis

دوره 27 2  شماره 

صفحات  -

تاریخ انتشار 2006