Reporting and analyzing dose distributions: a concept of equivalent uniform dose.
نویسنده
چکیده
Modern treatment planning systems for three-dimensional treatment planning provide three-dimensionally accurate dose distributions for each individual patient. These data open up new possibilities for more precise reporting and analysis of doses actually delivered to irradiated organs and volumes of interest. A new method of summarizing and reporting inhomogeneous dose distributions is reported here. The concept of equivalent uniform dose (EUD) assumes that any two dose distributions are equivalent if they cause the same radiobiological effect. In this paper the EUD concept for tumors is presented, for which the probability of local control is assumed to be determined by the expected number of surviving clonogens, according to Poisson statistics. The EUD can be calculated directly from the dose calculation points or, from the corresponding dose-volume distributions (histograms). The fraction of clonogens surviving a dose of 2 Gy (SF2) is chosen to be the primary operational parameter characterizing radiosensitivity of clonogens. The application of the EUD concept is demonstrated on a clinical dataset. The causes of flattening of the observed dose-response curves become apparent since the EUD concept reveals the finer structure of the analyzed group of patients in respect to the irradiated volumes and doses actually received. Extensions of the basic EUD concept to include nonuniform density of clonogens, dose per fraction effects, repopulation of clonogens, and inhomogeneity of patient population are discussed and compared with the basic formula.
منابع مشابه
Applying the equivalent uniform dose formulation based on the linear‐quadratic model to inhomogeneous tumor dose distributions: Caution for analyzing and reporting
We apply the concept of equivalent uniform dose (EUD) to our data set of model distributions and intensity modulated radiotherapy (IMRT) treatment plans as a method for analyzing large dose inhomogeneities within the tumor volume. For large dose nonuniformities, we find that the linerar-quadratic based EUD model is sensitive to the linear-quadratic model parameters, alpha and beta, making it ne...
متن کاملEffect of Tissue Composition on Dose Distribution in Electron Beam Radiotherapy
Objective: The aim of this study is to evaluate the effect of tissue composition on dose distribution in electron beam radiotherapy.Methods: A Siemens Primus linear accelerator and a phantom were simulated using MCNPX Monte Carlo code. In a homogeneous cylindrical phantom, six types of soft tissue and three types of tissue-equivalent materials were investigated. The tissues included muscle (ske...
متن کاملComparison dose distributions from gamma knife unit 4C with CT data and non-CT data options of beamnrc code
Todays gamma knife radiosurgery is used widely for treatment of very small brain tumors. In order to investigate accuracy of dosimetry and treatment planning calculations, using Monte Carlo simulation with dedicated code named as beamnrc including non-CT data and CT data options is necessary. The aim of this study is choosing the best options in order to have an accurate tools based on their ad...
متن کاملA free user friendly program for evaluation of radiotherapy plans based on different dose response models
Introduction: Radiotherapy (RT) plan evaluation using dose response models has become a feasible approach in routine clinical practice. Although there are several tools for this task, they suffer from limitations including number of different dose response models and parameters. In the present study, we aimed to develop a free program for RT plan evaluation based on a variety ...
متن کاملA dosimetric study of deep skin electron therapy with overlapping stationary radiation fields – A case report
Background: For radiotherapy of total skin including sub-cutaneous tissue up to a depth of 3 cm on the entire left leg of an adult (Angiosarcoma skin), a complex treatment with multiple stationary electron fields was planned at our clinic. The details of dosimetry, clinical dose measurements are presented. Materials and Methods: The treatment planned with 6 overlapping 9 MeV electron fields in ...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Medical physics
دوره 24 1 شماره
صفحات -
تاریخ انتشار 1997