Determinants of left ventricular preload-adjusted maximal power.
نویسندگان
چکیده
Maximal left ventricular (LV) hydraulic power output (PWR(max)), corrected for preload as PWR(max)/(V(ed))(beta) (where V(ed) is the end-diastolic volume and beta is a constant coefficient), is an index of LV contractility. Whereas preload-adjusted maximal power (PAMP) is usually calculated with beta = 2, there is uncertainty about the optimal value of beta (beta = 1 for the normal LV and 2 for the dilated LV). The aim of this work is to study the determining factors of beta. The data set consisted of 245 recordings (steady state and vena cava occlusion) in 10 animals in an ischemic heart pig model. The occlusion data yielded the slope (E(es); 2.01 +/- 0.77 mmHg/ml, range 0.71-4.16 mmHg/ml) and intercept (V(0); -11.9 +/- 22.6 ml; range -76 to 39 ml) of the end-systolic pressure-volume relation, and the optimal beta-factor (assessed by fitting an exponential curve through the V(ed)-PWR(max) relation) was 1.94 +/- 0.88 (range 0.29-4.73). The relation of beta with V(ed) was weak [beta = 0.60 + 0.02(V(ed)); r(2) = 0.20]. In contrast, we found an excellent exponential relation between V(0) and beta [beta = 2.16e(0.0189(V(0))), r(2) = 0.70]. PAMP, calculated from the steady-state data, was 0.64 +/- 0.40 mW/ml(2) (range 0.14-2.83 mW/ml(2)) with a poor correlation with E(es) (r = 0.30, P < 0.001). An alternative formulation of PAMP as PWR(max)/(V(ed) - V(0))(2), incorporating V(0), yielded 0.47 +/- 0.26 mW/ml(2) (range 0.09-1.42 mW/ml(2)) and was highly correlated with E(es) (r = 0.89, P < 0.001). In conclusion, correct preload adjustment of maximal LV power requires incorporation of V(0) and thus of data measured under altered loading conditions.
منابع مشابه
BASIC RESEARCH Preload-adjusted maximal power: a novel index of left ventricular contractility in atrial fibrillation
Background: Left ventricular contractility in atrial fibrillation is known to change in a beat to beat fashion, but there is no gold standard for contractility indices in atrial fibrillation, especially those measured non-invasively. Objective: To determine whether the non-invasive index of contractility “preload-adjusted PWRmax” (maximal ventricular power divided by the square of end diastolic...
متن کاملPreload-adjusted maximal power: a novel index of left ventricular contractility in atrial fibrillation.
BACKGROUND Left ventricular contractility in atrial fibrillation is known to change in a beat to beat fashion, but there is no gold standard for contractility indices in atrial fibrillation, especially those measured non-invasively. OBJECTIVE To determine whether the non-invasive index of contractility "preload-adjusted PWR(max)" (maximal ventricular power divided by the square of end diastol...
متن کاملPreload-adjusted right ventricular maximal power: concept and validation.
Right ventricular (RV) maximal power (PWR(mx)) is dependent on preload. The objective of this study was to test our hypothesis that the PWR(mx) versus end-diastolic volume (EDV) relationship, analogous to the load-independent stroke work (SW) versus EDV relationship (preload-recruitable SW, PRSW), is linear, with the PWR x-axis intercept (V(0PWR)) corresponding to the PRSW intercept (V(0SW)). I...
متن کاملPreload-adjusted maximal power of right ventricle: contribution of end-systolic P-V relation intercept.
To assess whether preload-adjusted maximal power (PAMP), which is calculated as W(max)/V (where W(max) is maximal power and V(ed) is end-diastolic volume with beta = 2) is an index of right ventricular (RV) contractility, we measured RV pressure (P) and volume (V) and pulmonary artery pressure and flow in 10 dogs at baseline and after inotropic stimulation. PAMP was derived from steady-state da...
متن کاملVentricular systolic assessment in patients with dilated cardiomyopathy by preload-adjusted maximal power. Validation and noninvasive application.
BACKGROUND Noninvasive cardiac-specific analysis of contractile function in patients with dilated heart failure remains problematic. This study tests whether maximal power divided by the square of end-diastolic volume (PWRmx/EDV2, or preload-adjusted PWRmx) can provide such assessment. METHODS AND RESULTS To validate the load insensitivity of the PWRmx index and determine its response to cont...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- American journal of physiology. Heart and circulatory physiology
دوره 284 6 شماره
صفحات -
تاریخ انتشار 2003