Impact of Appropriate Use on the Estimated Radiation Risk to Men and Women Undergoing Radionuclide Myocardial Perfusion Imaging.

نویسندگان

  • Rami Doukky
  • Nathan Frogge
  • Andrew Appis
  • Kathleen Hayes
  • George Khoudary
  • Louis Fogg
  • Kim A Williams
چکیده

UNLABELLED The impact of appropriate use criteria (AUC) for myocardial perfusion imaging (MPI) with SPECT on the estimated lifetime attributable risk (LAR) of cancer is unknown. METHODS A cohort of 1,511 consecutive patients who underwent clinically indicated (99m)Tc-setamibi MPI were categorized into appropriate/uncertain (n = 823) versus inappropriate (n = 688) use groups according to the 2009 AUC and were prospectively followed for 27 ± 10 mo. Logistic regression models were used to determine the annualized probability of major adverse cardiac events (MACE) of cardiac death or myocardial infarction and the probability of revascularization within 6 mo of MPI, accounting for relevant covariates. We determined LAR for each subject on the basis of accepted risk estimates. We calculated MPI's benefit-to-risk ratios, defined by the annualized predicted MACE-to-LAR ratio and the predicted 6-mo-revascularization-to-LAR ratio. RESULTS During follow-up, there were 22 MACE and 29 6-mo revascularizations. The administered radioactivity and effective radiation doses absorbed were similar between the study groups. Patients with inappropriate MPI had significantly higher LAR (median, 0.08% vs. 0.06%, P < 0.001), lower predicted MACE-to-LAR ratio (median, 1.5 vs. 4.3, P < 0.001), and lower predicted 6-mo-revascularization-to-LAR ratio (median, 5.4 vs. 15.5, P < 0.001). Women had higher LAR (median, 0.08% vs. 0.07%, P < 0.001) and lower predicted MACE-to-LAR ratio (median, 1.9 vs. 3.3, P < 0.001) and 6-mo-revascularization-to-LAR ratio (median, 4.4 vs. 17.5, P < 0.001). However, appropriate/uncertain use negated the difference between men and women in LAR (P = 0.94) and the predicted MACE-to-LAR ratio (P = 0.97). CONCLUSION Inappropriate MPI use is associated with excess cancer risk and lower MPI's benefit-to-risk ratio. Appropriate/uncertain use neutralizes the sex gap in LAR with MPI.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Detection of Cardiac Artery Disease by Using the DCAD (b) Module

Introduction: In patients with cardiac artery disease, a myocardial perfusion scan, which is a non-invasive method, is utilized. This study is conducted to develop an advantageous software applicable to quantitative myocardial SPECT perfusion. Material and Methods: Each cross-section of the left ventricle was segmented by applying a fuzzy clustering method. After obtaining the myocardial skelet...

متن کامل

Determination of Uterus Absorbed Dose by Patients following Myocardial Perfusion Scan using TLD and Conjugate View Methods

Introduction: The determination of patient’s absorbed dose is the first step of radiation protection which depends on the quantification of organ activity in nuclear medicine. The aim of the present study was to determine the absorbed dose by patient’s uterus following myocardial perfusion scan with 99mTC-sestamibi using Theroluminescnce dosimetry (TLD) and conjugate-view metho...

متن کامل

Myocardial Perfusion SPECT Imaging in Dextrocardia with Situs Inversus: A Case Report

Dextrocardia is a cardiac positional anomaly in which the heart is located in the right hemithorax with its base-to-apex axis directed to the right and caudad. Situs inversus is an autosomal recessive disorder that causes organs in the chest and abdomen to be positioned in a mirror image from their normal position. Dextrocardia may occur in isolation or as part of situs inversus. Similarly, sit...

متن کامل

Covid-19 manifestation on Tl-201 myocardial perfusion SPECT/CT

A 67 years old woman was referred to nuclear medicine center for myocardial perfusion imaging (MPI) for assessment of ischemic heart dieses (IHD).She had a history of atypical chest pain and dyspnea since about 10 days before admission. The MPI SPECT/CT was performed by stress/redistribution Tl-201 protocol. MPI was interpreted as relatively good coronary flow with no appreciable stress induced...

متن کامل

Radiation-induced myocardial perfusion abnormalities in breast cancer patients following external beam radiation therapy

Objective(s): Radiation therapy for breast cancer can induce myocardial capillary injury and increase cardiovascular morbidity and mortality. A prospective cohort was conducted to study the prevalence of myocardial perfusion abnormalities following radiation therapy of left-sided breast cancer patients as compared to those with right–sided cancer. Methods: To minimize potential confounding fact...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Journal of nuclear medicine : official publication, Society of Nuclear Medicine

دوره 57 8  شماره 

صفحات  -

تاریخ انتشار 2016