Diffusion-Weighted Imaging with Color-Coded Images: Towards a Reduction in Reading Time While Keeping a Similar Accuracy

نویسندگان

  • Felipe Campos Kitamura
  • Srhael de Medeiros Alves
  • Luis Antônio Tobaru Tibana
  • Nitamar Abdala
چکیده

The aim of this study was to develop a diagnostic tool capable of providing diffusion and apparent diffusion coefficient (ADC) map information in a single color-coded image and to assess the performance of color-coded images compared with their corresponding diffusion and ADC map. The institutional review board approved this retrospective study, which sequentially enrolled 36 head MRI scans. Diffusion-weighted images (DWI) and ADC maps were compared to their corresponding color-coded images. Four raters had their interobserver agreement measured for both conventional (DWI) and color-coded images. Differences between conventional and color-coded images were also estimated for each of the 4 raters. Cohen's kappa and percent agreement were used. Also, paired-samples t-test was used to compare reading time for rater 1. Conventional and color-coded images had substantial or almost perfect agreement for all raters. Mean reading time of rater 1 was 47.4 seconds for DWI and 27.9 seconds for color-coded images (P = .00007). These findings are important because they support the role of color-coded images as being equivalent to that of the conventional DWI in terms of diagnostic capability. Reduction in reading time (which makes the reading easier) is also demonstrated for one rater in this study.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Practical visualization of internal structure of white matter for image interpretation: staining a spin-echo T2-weighted image with three echo-planar diffusion-weighted images.

BACKGROUND AND PURPOSE To our knowledge, no method satisfactory for clinical use has been developed to visualize white matter fiber tracts with diffusion-weighted MR imaging. The purpose of this study was to determine whether superposition of a spin-echo T2-weighted image and a color-coded image derived from three orthogonal diffusion-weighted images could show fiber tract architecture of the b...

متن کامل

Planar and SPECT Monte Carlo acceleration using a variance reduction technique in I131 imaging

Background: Various variance reduction techniques such as forced detection (FD) have been implemented in Monte Carlo (MC) simulation of nuclear medicine in an effort to decrease the simulation time while keeping accuracy. However most of these techniques still result in very long MC simulation times for being implemented into routine use. Materials and Methods: Convolution-based force...

متن کامل

Dual-time-point FDG-PET/CT Imaging of Temporal Bone Chondroblastoma: A Report of Two Cases

Temporal bone chondroblastoma is an extremely rare benign bone tumor. We encountered two cases showing similar imaging findings on computed tomography (CT), magnetic resonance imaging (MRI), and dual-time-point 18F-fluorodeoxyglucose (18F-FDG) positron emission tomography (PET)/CT. In both cases, CT images revealed temporal bone defects and sclerotic changes around the tumor. Most parts of the ...

متن کامل

Differentiation of active tumor from edematous regions of glioblastoma multiform tumor in diffusion MR images using heterogeneity analysis method

Background: Due to intrinsic heterogeneity of cellular distribution and density within diffusion weighted images (DWI) of glioblastoma multiform (GBM) tumors, differentiation of active tumor and peri-tumoral edema regions within these tumors is challenging. The aim of this paper was to take advantage of the differences among heterogeneity of active tumor and edematous regions within the gliobla...

متن کامل

Color-coded fluid-attenuated inversion recovery images improve inter-rater reliability of fluid-attenuated inversion recovery signal changes within acute diffusion-weighted image lesions.

BACKGROUND AND PURPOSE Diffusion-weighted image fluid-attenuated inversion recovery (FLAIR) mismatch has been considered to represent ischemic lesion age. However, the inter-rater agreement of diffusion-weighted image FLAIR mismatch is low. We hypothesized that color-coded images would increase its inter-rater agreement. METHODS Patients with ischemic stroke <24 hours of a clear onset were re...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:

دوره 2016  شماره 

صفحات  -

تاریخ انتشار 2016