Clinical efficacy of polymer-based paclitaxel-eluting stents in the treatment of complex, long coronary artery lesions from a multicenter, randomized trial: support for the use of drug-eluting stents in contemporary clinical practice.

نویسندگان

  • Keith D Dawkins
  • Eberhard Grube
  • Giulio Guagliumi
  • Adrian P Banning
  • Krzysztof Zmudka
  • Antonio Colombo
  • Leif Thuesen
  • Karl Hauptman
  • Jean Marco
  • William Wijns
  • Jeffrey J Popma
  • Joerg Koglin
  • Mary E Russell
چکیده

BACKGROUND Intracoronary polymer-based stent delivery of paclitaxel has been shown to be effective in reducing restenosis in simple coronary lesions, but the evidence base for contemporary use in longer, more complex coronary stenoses is lacking. METHODS AND RESULTS TAXUS VI is a prospective, multicenter, double-blind, randomized trial assessing clinical and angiographic outcomes of the TAXUS Moderate Release paclitaxel-eluting stent in the treatment of long, complex coronary artery lesions. Four hundred forty-eight patients at 44 sites were randomized (1:1) between a drug-eluting TAXUS Express2 and an uncoated Express2 control stent. Per protocol, the 9-month follow-up included an angiographic reevaluation in all patients. The primary end point was the rate of target-vessel revascularization 9 months after the study procedure; secondary end points included the rate of target-lesion revascularization and binary restenosis at follow-up. Mean lesion length in the study was 20.6 mm, with a mean stent-covered length of 33.4 mm. Of all lesions, 55.6% were classified as complex lesions (type C of the AHA/ACC classification). At 9 months, target-vessel revascularization was 9.1% in the TAXUS group and 19.4% in the control group (P=0.0027; relative reduction, 53%). Target-lesion revascularization was reduced from 18.9% to 6.8%, respectively (P=0.0001). The incidence of major adverse cardiac events was similar in the 2 groups, 16.4% and 22.5% in TAXUS and control, respectively (P=0.12), including comparable rates for acute myocardial infarction. Binary restenosis in the stented area was reduced from 32.9% in the control group to 9.1% in the TAXUS patients (P<0.0001). CONCLUSIONS The finding that the TAXUS Moderate Release stent system is safe and effective in the treatment of long, complex coronary artery lesions provides the evidence base for the more widespread use of drug-eluting stents in contemporary clinical practice.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

نتایج بالینی پس از آنژیوپلاستی عروق کرونر، بروز حوادث بزرگ قلبی-عروقی و عوارض انواع استنت

Background: Cardiovascular diseases alone have become the leading cause of death worldwide. One of the treatment methods cardiovascular disease is angioplasty. This study aimed to investigate the clinical results after coronary artery angioplasty, based on the incidence of major cardiovascular events with emphasis on stent types. Methods: In this retrospective cross-sectional study, the preval...

متن کامل

Impact of lesion length and vessel size on clinical outcomes after percutaneous coronary intervention with everolimus- versus paclitaxel-eluting stents pooled analysis from the SPIRIT (Clinical Evaluation of the XIENCE V Everolimus Eluting Coronary Stent System) and COMPARE (Second-generation everolimus-eluting and paclitaxel-eluting stents in real-life practice) Randomized Trials.

OBJECTIVES The aim of this study was to investigate the impact of reference vessel diameter (RVD) and lesion length (LL) on the relative safety and efficacy of everolimus-eluting stents (EES) and paclitaxel-eluting stents (PES). BACKGROUND Lesion length and RVD are well-known predictors of adverse events after percutaneous coronary intervention. METHODS Patient-level data were pooled from t...

متن کامل

Polymer-free sirolimus-eluting versus polymer-based paclitaxel-eluting stents: an individual patient data analysis of randomized trials.

INTRODUCTION AND OBJECTIVES The angiographic and clinical efficacy of polymer-free sirolimus-eluting stents vs polymer-based paclitaxel-eluting stents remain a matter of debate. We sought to investigate angiographic and clinical measures of efficacy of polymer-free sirolimus-eluting stents vs polymer-based paclitaxel-eluting stents. METHODS Patient data from the randomized intracoronary stent...

متن کامل

The "final" 5-year follow-up from the ENDEAVOR IV trial comparing a zotarolimus-eluting stent with a paclitaxel-eluting stent.

OBJECTIVES This study sought to report the final 5-year outcomes of the ENDEAVOR IV (A Randomized, Controlled Trial of the Medtronic Endeavor Drug [ABT-578] Eluting Coronary Stent System Versus the Taxus Paclitaxel-Eluting Coronary Stent System in De Novo Native Coronary Artery Lesions) trial comparing the Endeavor zotarolimus-eluting stent (E-ZES) (Medtronic, Santa Rosa, California) with the T...

متن کامل

Bare metal stents, durable polymer drug eluting stents, and biodegradable polymer drug eluting stents for coronary artery disease: mixed treatment comparison meta-analysis

OBJECTIVE To compare the efficacy and safety of biodegradable polymer drug eluting stents with those of bare metal stents and durable polymer drug eluting stents. DESIGN Mixed treatment comparison meta-analysis of 258,544 patient years of follow-up from randomized trials. DATA SOURCES AND STUDY SELECTION PubMed, Embase, and Central were searched for randomized trials comparing any of the Fo...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Circulation

دوره 112 21  شماره 

صفحات  -

تاریخ انتشار 2005