Fast pinless external fixation for open tibial fractures: preliminary report of a prospective study.

نویسندگان

  • Zheyuan Huang
  • Bowen Wang
  • Fengrong Chen
  • Jianming Huang
  • Guojian Jian
  • Hao Gong
  • Tianrui Xu
  • Ruisong Chen
  • Xiaolin Chen
  • Zhiyang Ye
  • Jun Wang
  • Desheng Xie
  • Haoyuan Liu
چکیده

A major drawback of conventional fixator system is the penetration of fixator pins into the medullary canal. The pins create a direct link between the medullary cavity and outer environment, leading to higher infection rates on conversion to intramedullary nailing. This study was designed to prospectively evaluate the role of new rapid pinless external fixators in primary stabilization of open tibial shaft fractures. In our study, a prospective study of 96 consecutive patients of open tibial shaft fractures treated with new rapid pinless external fixator and reamed intramedullary nail was carried out. The bone healing status, ability to maintain alignment were examined for radiologic outcome, whereas initial management, length of hospital stay, associated morbidity, range of knee and ankle motion, time to partial and full weight-bearing, employment status and perioperative and postoperative complications were used for clinical evaluation. We followed up for over two years for the patients underwent clinical and radiologic after the surgery. The mean hospital stay was 15 days (ranges, 8-68). Bone healing was achieved for all cases except 3 patients who were lost to follow-up study. No patient suffered compartment syndromes. There was no statistically significance in range of motion among the knees of injury and uninjured limbs at final follow-up (P > 0.05). To the last follow-up, there were no cases of deep infection or implant-related fractures. Seventy-one patients who were employed before the injury returned to work after the operation, 16 had changed to less strenuous work. We concluded that better results can be achieved on clinical and radiologic evaluation of primary stabilization with rapid pinless external fixator and early exchange reamed intramedullary nail for suitable patients with open tibial shaft fractures. The incident rate of relative complications is low. The rapid pinless external fixator can be combined favorably with the reamed intramedullary nail and is a valuable addition to the conventional external fixator systems.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Treatment of Open Tibial Fractures: Convert-ing or Continuing External Fixation?

Background: The treatment of open tibial fractures is still an orthopaedic challenge and full of complications. In many cases the use of external fixator that has been known as a non-union machine is obligatory with a high incidence of pin track infection and other complications. The aim of this study was to compare the use of external fixation as a definite method for treatment of open tibial ...

متن کامل

Experience with the pinless fixator in the treatment of fractures of the lower leg.

This is a report of the experience we have gathered in the application of the pinless fixator in cases of tibial fracture with soft tissue damage. In the Berufsgenossenschaftlichen Unfallklinik Ludwigshafen (Clinic for Trauma Surgery) 12 diaphyseal fractures of the tibia were stabilized with the pinless fixator in 1991. In all cases, conversion to an intramedullary nail was intended from the ve...

متن کامل

Open tibial shaft fractures. Treatment with intramedullary nailing after provisional stabilization with non penetrating external fixator

Objective: To evaluate the incidence of union, nonunion, deep infection and factors influencing the time of bone healing in the treatment of open tibial shaft fractures Gustilo and Anderson types I and II initially treated with a non penetrating external fixator (Pinless®) followed by an unreamed intramedullary locked nail (UTN®). Methods: It is a prospective study of 39 open tibial shaft fract...

متن کامل

مقایسه اکسترنال فیکساتور با اینتـرامدولاری نیلینگ در درمان شکستگی‌های باز تیبیا

Background and purpose: Ëxternal fixation is currently considered as a standard treatment for open tibial fractures however, due to the long-term hospitalization and some other complications, some researchers have proposed intramedullary nailing as the alternative surgical treatment. This study was conducted to compare the treatment of open tibial shaft fractures by external fixation and int...

متن کامل

Treatment of Grade-iiib Open Tibial Fractures

Severe open fractures of the tibia have a high incidence of complications and a poor outcome. The most usual method of stabilisation is by external fixation, but the advent of small diameter locking intramedullary nails has introduced a new option. We report the early results of a randomised, prospective study comparing external fixation with non-reamed locked nails in grade-IIIb open tibial fr...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • International journal of clinical and experimental medicine

دوره 8 11  شماره 

صفحات  -

تاریخ انتشار 2015