The outcomes of continuous ambulatory and automated peritoneal dialysis are similar.

نویسندگان

  • Rajnish Mehrotra
  • Yi-Wen Chiu
  • Kamyar Kalantar-Zadeh
  • Edward Vonesh
چکیده

Recent reports indicate a decreased mortality risk for patients on chronic peritoneal dialysis in the United States. We sought to determine whether a higher use of automated versus continuous ambulatory peritoneal dialysis was associated with this improvement. Analyses were carried out using data from the United States Renal Data System on 66,381 incident patients on chronic peritoneal dialysis in the years 1996-2004 that were adjusted for demographic, clinical, laboratory and dialysis facility characteristics. Patients were followed until the time of transfer to other modes of dialysis, transplant, or death, whichever occurred first, or until their last follow-up through September 2006. Over time, the risks were substantially reduced such that the adjusted hazard ratios for death or technique failure of these patients in the 2002-2004 period were 0.55 (0.53, 0.57) and 0.62 (0.59, 0.64), respectively, compared with those of incident patients during the years 1996-1998. The risk improvements for both modes of dialysis were, however, found to be similar. Under intent-to-treat, time-dependent, and as-treated analysis, there was little or no difference in risk for death or in technique failure. Thus, the improved chronic peritoneal dialysis outcomes cannot be attributed to a greater use of automated peritoneal dialysis.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Correlation between Ultrafiltration Coefficient and Effective Lymphatic Absorption Rate in Continuous Ambulatory Peritoneal Dialysis Patients: A Possible Paradigm Shift

Background: The relative contribution of transcapillary water movement and lymphatic reabsorption in peritoneal dialysis (PD) is a critical issue, particularly in patients with ultrafiltration failure (UFF). Based on routine results obtained from the PD Adequest 2.0 software, the present study aimed to re-evaluate the separate effects of transcapillary water movement and lymphatic reabsorption ...

متن کامل

Do Automated Peritoneal Dialysis and Continuous Ambulatory Peritoneal Dialysis Have the Same Clinical Outcomes? A Ten-year Cohort Study in Taiwan

This paper reports a comprehensive comparison for mortality and technique failure rates between automated peritoneal dialysis (APD) and continuous ambulatory peritoneal dialysis (CAPD) in Taiwan. A propensity-score matched cohort study was conducted by retrieving APD and CAPD patients identified from the Taiwan National Health Insurance Research Database between 2001 and 2010. The main outcomes...

متن کامل

ارایه مدلی جهت پیش‌بینی بقای بیماران دیالیز صفاقی با استفاده از الگوریتم‌های داده‌کاوی

Background: Peritoneal dialysis is one of the most commonly used treatment methods for the patients with end stage renal failure. In recent years, the mortality rate of patients under this treatment has decreased; however, long-term survival is still an important challenge for health systems. The present study aimed to predict the survival of continuous ambulatory peritoneal dialysis patients. ...

متن کامل

Effectiveness of Automated Peritoneal Dialysis Compared to Outpatient Procedure: A Systematic Review and Meta-analysis Study

Introduction: The growing trend of renal failure has focused clinical therapy on the cost-effective alternatives such as peritoneal dialysis. Therefore, the present study has investigated the effectiveness of two methods of continuous and automatic peritoneal dialysis in the patients with end stage renal disease. Methods: This study was conducted in the form of a systematic review. Advanced se...

متن کامل

Developing a Device for Automated Peritoneal Dialysis

Background: Peritoneal dialysis (PD) is an efficient alternative for hemodialysis. Removal of waste metabolites and excess water from the blood circulation are the two main tasks done during dialysis. These are done by using a filter; in PD, the naturally semi-permeable peritoneal membrane acts as the filter. Automated PD machines control intelligently the operations to enhance the efficiency a...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:
  • Kidney international

دوره 76 1  شماره 

صفحات  -

تاریخ انتشار 2009